Zone HVAC Forced Air Units

16 object types from idfpy.models.zone_forced_air · EnergyPlus 26.2

Object Summary
ZoneHVAC:Dehumidifier:DX This object calculates the performance of zone (room) air dehumidifiers.
ZoneHVAC:EnergyRecoveryVentilator This compound component models a stand-alone energy recovery ventilator (ERV) that conditions outdoor …
ZoneHVAC:EnergyRecoveryVentilator:Controller This controller is used exclusively by the ZoneHVAC:EnergyRecoveryVentilator object to allow economizer (free …
ZoneHVAC:EvaporativeCoolerUnit Zone evaporative cooler.
ZoneHVAC:FourPipeFanCoil Four pipe fan coil system.
ZoneHVAC:HybridUnitaryHVAC Hybrid Unitary HVAC.
ZoneHVAC:IdealLoadsAirSystem Ideal system used to calculate loads without modeling a full HVAC system.
ZoneHVAC:OutdoorAirUnit The zone outdoor air unit models a single-zone dedicated outdoor air system (DOAS).
ZoneHVAC:OutdoorAirUnit:EquipmentList Equipment list for components in a ZoneHVAC:OutdoorAirUnit.
ZoneHVAC:PackagedTerminalAirConditioner Packaged terminal air conditioner (PTAC).
ZoneHVAC:PackagedTerminalHeatPump Packaged terminal heat pump (PTHP).
ZoneHVAC:TerminalUnit:VariableRefrigerantFlow A terminal unit with variable refrigerant flow (VRF) DX cooling and heating coils (air-to-air heat pump).
ZoneHVAC:UnitHeater Unit heater.
ZoneHVAC:UnitVentilator Unit ventilator.
ZoneHVAC:WaterToAirHeatPump Water-to-air heat pump.
ZoneHVAC:WindowAirConditioner Window air conditioner.

ZoneHVAC:Dehumidifier:DX

from idfpy.models import ZoneHVACDehumidifierDX

This object calculates the performance of zone (room) air dehumidifiers. Meant to model conventional direct expansion (DX) cooling-based room air dehumidifiers (reject 100% of condenser heat to the zone air), but this object might be able to be used to model other room air dehumidifier types.

Field Type Default Details
name
Name required
string Unique name for this direct expansion (DX) zone dehumidifier object.
availability_schedule_name
Availability Schedule Name
reference Availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available. Schedule values of 0 denote the unit is off. Schedule values >0.0 (usually 1.0) indicate that the dehumidifier is available to operate.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
air_inlet_node_name
Air Inlet Node Name required
string Air inlet node for the dehumidifier must be a zone air exhaust node.
air_outlet_node_name
Air Outlet Node Name required
string Air outlet node for the dehumidifier must be a zone air inlet node.
rated_water_removal
Rated Water Removal required
number
L/day
Rating point: air entering dehumidifier at 26.7 C (80 F) dry-bulb and 60% relative humidity.
Range: > 0
rated_energy_factor
Rated Energy Factor required
number
L/kWh
Rating point: air entering dehumidifier at 26.7 C (80 F) dry-bulb and 60% relative humidity.
Range: > 0
rated_air_flow_rate
Rated Air Flow Rate required
number
m3/s
Range: > 0
water_removal_curve_name
Water Removal Curve Name required
reference Name of a curve that describes the water removal rate (normalized to rated conditions) as a function of the dry-bulb temperature and relative humidity of the air entering the dehumidifier. Curve output = (actual water removal/rated water removal) = a + b*T + c*T**2 + d*RH + e*RH**2 + f*T*RH T = inlet air dry-bulb temperature (C) RH = inlet air RH (%)
Names a Curve:Bicubic, Curve:Biquadratic, Curve:CubicLinear, Curve:FanPressureRise, Curve:QuadraticLinear, Table:Lookup
energy_factor_curve_name
Energy Factor Curve Name required
reference Name of a curve that describes the energy factor (normalized to rated conditions) as a function of the dry-bulb temperature and relative humidity of the air entering the dehumidifier. Curve output = (actual energy factor/rated energy factor) = a + b*T + c*T**2 + d*RH + e*RH**2 + f*T*RH T = inlet air dry-bulb temperature (C) RH = inlet air RH (%)
Names a Curve:Bicubic, Curve:Biquadratic, Curve:CubicLinear, Curve:FanPressureRise, Curve:QuadraticLinear, Table:Lookup
part_load_fraction_correlation_curve_name
Part Load Fraction Correlation Curve Name required
reference Name of a curve that describes the part load fraction (PLF) of the system as a function of the part load ratio. Used to calculate dehumidifier run time fraction and electric power. quadratic curve = a + b*PLR + c*PLR**2 cubic curve = a + b*PLR + c*PLR**2 + d*PLR**3 PLR = part load ratio (dehumidification load/steady state water removal capacity)
Names a Curve:Cubic, Curve:DoubleExponentialDecay, Curve:Exponent, Curve:ExponentialDecay, Curve:ExponentialSkewNormal, Curve:Functional:PressureDrop, Curve:Linear, Curve:Quadratic, Curve:Quartic, Curve:RectangularHyperbola1, Curve:RectangularHyperbola2, Curve:Sigmoid and 1 more
minimum_dry_bulb_temperature_for_dehumidifier_operation
Minimum Dry-Bulb Temperature for Dehumidifier Operation
number
C
10.0 Dehumidifier shut off if inlet air (zone) temperature is below this value. This value must be less than the Maximum Dry-Bulb Temperature for Dehumidifier Operation.
maximum_dry_bulb_temperature_for_dehumidifier_operation
Maximum Dry-Bulb Temperature for Dehumidifier Operation
number
C
35.0 Dehumidifier shut off if inlet air (zone) temperature is above this value. This value must be greater than the Minimum Dry-Bulb Temperature for Dehumidifier Operation.
off_cycle_parasitic_electric_load
Off-Cycle Parasitic Electric Load
number
W
0.0 Parasitic electric power consumed when the dehumidifier is available to operate, but does not operate (i.e., no high humidity load to be met). Off cycle parasitic power is 0 when the availability schedule is 0. This electric load is considered as a heat gain to the zone air.
Range: ≥ 0
condensate_collection_water_storage_tank_name
Condensate Collection Water Storage Tank Name
reference Name of storage tank used to collect water removed by the dehumidifier.
Names a WaterUse:Storage
Referenced by 2 object types

SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList

ZoneHVAC:EnergyRecoveryVentilator

from idfpy.models import ZoneHVACEnergyRecoveryVentilator

This compound component models a stand-alone energy recovery ventilator (ERV) that conditions outdoor ventilation air and supplies that air directly to a zone. The ERV unit is modeled as a collection of components: air-to-air heat exchanger, supply air fan, exhaust air fan and an optional controller to avoid overheating of the supply air (economizer or free cooling operation).

Field Type Default Details
name
Name required
string
availability_schedule_name
Availability Schedule Name
reference Availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
heat_exchanger_name
Heat Exchanger Name required
reference Heat exchanger type must be HeatExchanger:AirToAir:SensibleAndLatent
Names a HeatExchanger:AirToAir:SensibleAndLatent
supply_air_flow_rate
Supply Air Flow Rate required
number or Autosize
m3/s
This flow rate must match the supply fan's air flow rate.
exhaust_air_flow_rate
Exhaust Air Flow Rate required
number or Autosize
m3/s
This flow rate must match the supply fan air flow rate.
supply_air_fan_name
Supply Air Fan Name required
reference Fan type must be Fan:OnOff or Fan:SystemModel
Names a Fan:OnOff, Fan:SystemModel
exhaust_air_fan_name
Exhaust Air Fan Name required
reference Fan type must be Fan:OnOff or Fan:SystemModel
Names a Fan:OnOff, Fan:SystemModel
controller_name
Controller Name
reference Enter the name of a ZoneHVAC:EnergyRecoveryVentilator:Controller object.
Names a ZoneHVAC:EnergyRecoveryVentilator:Controller
ventilation_rate_per_unit_floor_area
Ventilation Rate per Unit Floor Area
number
m3/s-m2
0.000508 m3/s-m2 corresponds to 0.1 ft3/min-ft2 Used only when supply and exhaust air flow rates are autosized.
Range: ≥ 0
ventilation_rate_per_occupant
Ventilation Rate per Occupant
number
m3/s-person
0.00236 m3/s-person corresponds to 5 ft3/min-person Used only when supply and exhaust air flow rates are autosized.
Range: ≥ 0
availability_manager_list_name
Availability Manager List Name
reference Enter the name of an AvailabilityManagerAssignmentList object.
Names a AvailabilityManagerAssignmentList
Referenced by 2 object types

SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList

ZoneHVAC:EnergyRecoveryVentilator:Controller

from idfpy.models import ZoneHVACEnergyRecoveryVentilatorController

This controller is used exclusively by the ZoneHVAC:EnergyRecoveryVentilator object to allow economizer (free cooling) operation when possible.

Field Type Default Details
name
Name required
string
temperature_high_limit
Temperature High Limit
number
C
Enter the maximum outdoor dry-bulb temperature limit for economizer operation. No input or blank input means this limit is not operative
temperature_low_limit
Temperature Low Limit
number
C
Enter the minimum outdoor dry-bulb temperature limit for economizer operation. No input or blank input means this limit is not operative
enthalpy_high_limit
Enthalpy High Limit
number
J/kg
Enter the maximum outdoor enthalpy limit for economizer operation. No input or blank input means this limit is not operative
dewpoint_temperature_limit
Dewpoint Temperature Limit
number
C
Enter the maximum outdoor dew point temperature limit for economizer operation. No input or blank input means this limit is not operative
electronic_enthalpy_limit_curve_name
Electronic Enthalpy Limit Curve Name
reference Enter the name of a quadratic or cubic curve which defines the maximum outdoor humidity ratio (function of outdoor dry-bulb temperature) for economizer operation. No input or blank input means this limit is not operative
Names a Curve:Cubic, Curve:DoubleExponentialDecay, Curve:Exponent, Curve:ExponentialDecay, Curve:ExponentialSkewNormal, Curve:Functional:PressureDrop, Curve:Linear, Curve:Quadratic, Curve:Quartic, Curve:RectangularHyperbola1, Curve:RectangularHyperbola2, Curve:Sigmoid and 1 more
exhaust_air_temperature_limit
Exhaust Air Temperature Limit
choice NoExhaustAirTemperatureLimit One of ExhaustAirTemperatureLimit, NoExhaustAirTemperatureLimit
exhaust_air_enthalpy_limit
Exhaust Air Enthalpy Limit
choice NoExhaustAirEnthalpyLimit One of ExhaustAirEnthalpyLimit, NoExhaustAirEnthalpyLimit
time_of_day_economizer_flow_control_schedule_name
Time of Day Economizer Flow Control Schedule Name
reference Schedule values greater than 0 indicate economizer operation is active. This schedule may be used with or without the High Humidity Control option. When used together, high humidity control has priority over economizer control.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
high_humidity_control_flag
High Humidity Control Flag
choice No Select Yes to modify air flow rates based on a zone humidistat. Select No to disable this feature.
One of No, Yes
humidistat_control_zone_name
Humidistat Control Zone Name
reference Enter the name of the zone where the humidistat is located.
Names a Zone
high_humidity_outdoor_air_flow_ratio
High Humidity Outdoor Air Flow Ratio
number 1.0 Enter the ratio of supply (outdoor) air to the maximum supply air flow rate when modified air flow rates are active based on high indoor humidity.
Range: > 0
control_high_indoor_humidity_based_on_outdoor_humidity_ratio
Control High Indoor Humidity Based on Outdoor Humidity Ratio
choice Yes If NO is selected, the air flow rate is modified any time indoor relative humidity is above humidistat setpoint. If YES is selected, outdoor air flow rate is modified any time indoor relative humidity is above the humidistat setpoint AND the outdoor humidity ratio is less than the indoor humidity ratio.
One of No, Yes
Referenced by 1 object types

ZoneHVAC:EnergyRecoveryVentilator

ZoneHVAC:EvaporativeCoolerUnit

from idfpy.models import ZoneHVACEvaporativeCoolerUnit

Zone evaporative cooler. Forced-convection cooling-only unit with supply fan, 100% outdoor air supply. Optional relief exhaust node

Field Type Default Details
name
Name required
string
availability_schedule_name
Availability Schedule Name
reference Availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
availability_manager_list_name
Availability Manager List Name
reference Enter the name of an AvailabilityManagerAssignmentList object.
Names a AvailabilityManagerAssignmentList
outdoor_air_inlet_node_name
Outdoor Air Inlet Node Name required
string this is an outdoor air node
cooler_outlet_node_name
Cooler Outlet Node Name required
string this is a zone inlet node
zone_relief_air_node_name
Zone Relief Air Node Name
string this is a zone exhaust node, optional if flow is being balanced elsewhere
supply_air_fan_object_type
Supply Air Fan Object Type required
choice One of Fan:ComponentModel, Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel, Fan:VariableVolume
supply_air_fan_name
Supply Air Fan Name required
reference Names a Fan:ComponentModel, Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel, Fan:VariableVolume
design_supply_air_flow_rate
Design Supply Air Flow Rate required
number or Autosize
m3/s
fan_placement
Fan Placement required
choice One of BlowThrough, DrawThrough
cooler_unit_control_method
Cooler Unit Control Method required
choice One of ZoneCoolingLoadOnOffCycling, ZoneCoolingLoadVariableSpeedFan, ZoneTemperatureDeadbandOnOffCycling
throttling_range_temperature_difference
Throttling Range Temperature Difference
number
deltaC
1.0 used for ZoneTemperatureDeadbandOnOffCycling hysteresis range for thermostatic control
Range: > 0
cooling_load_control_threshold_heat_transfer_rate
Cooling Load Control Threshold Heat Transfer Rate
number
W
100.0 Sign convention is that positive values indicate a cooling load
Range: > 0
first_evaporative_cooler_object_type
First Evaporative Cooler Object Type required
choice One of EvaporativeCooler:Direct:CelDekPad, EvaporativeCooler:Direct:ResearchSpecial, EvaporativeCooler:Indirect:CelDekPad, EvaporativeCooler:Indirect:ResearchSpecial, EvaporativeCooler:Indirect:WetCoil
first_evaporative_cooler_object_name
First Evaporative Cooler Object Name required
reference Names a EvaporativeCooler:Direct:CelDekPad, EvaporativeCooler:Direct:ResearchSpecial, EvaporativeCooler:Indirect:CelDekPad, EvaporativeCooler:Indirect:ResearchSpecial, EvaporativeCooler:Indirect:WetCoil
second_evaporative_cooler_object_type
Second Evaporative Cooler Object Type
choice optional, used for direct/indirect configurations second cooler must be immediately downstream of first cooler, if present
One of EvaporativeCooler:Direct:CelDekPad, EvaporativeCooler:Direct:ResearchSpecial, EvaporativeCooler:Indirect:CelDekPad, EvaporativeCooler:Indirect:ResearchSpecial, EvaporativeCooler:Indirect:WetCoil
second_evaporative_cooler_name
Second Evaporative Cooler Name
reference optional, used for direct/indirect configurations
Names a EvaporativeCooler:Direct:CelDekPad, EvaporativeCooler:Direct:ResearchSpecial, EvaporativeCooler:Indirect:CelDekPad, EvaporativeCooler:Indirect:ResearchSpecial, EvaporativeCooler:Indirect:WetCoil
design_specification_zonehvac_sizing_object_name
Design Specification ZoneHVAC Sizing Object Name
reference Enter the name of a DesignSpecificationZoneHVACSizing object.
Names a DesignSpecification:ZoneHVAC:Sizing
shut_off_relative_humidity
Shut Off Relative Humidity
number
percent
Zone relative humidity above which the evap cooler is shut off.
Range: ≥ 0, ≤ 100
Referenced by 2 object types

SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList

ZoneHVAC:FourPipeFanCoil

from idfpy.models import ZoneHVACFourPipeFanCoil

Four pipe fan coil system. Forced-convection hydronic heating-cooling unit with supply fan, hot water heating coil, chilled water cooling coil, and fixed-position outdoor air mixer.

Field Type Default Details
name
Name required
string
availability_schedule_name
Availability Schedule Name
reference Availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
capacity_control_method
Capacity Control Method required
choice One of ASHRAE90VariableFan, ConstantFanVariableFlow, CyclingFan, MultiSpeedFan, VariableFanConstantFlow, VariableFanVariableFlow
maximum_supply_air_flow_rate
Maximum Supply Air Flow Rate required
number or Autosize
m3/s
low_speed_supply_air_flow_ratio
Low Speed Supply Air Flow Ratio
number 0.33 Range: > 0
medium_speed_supply_air_flow_ratio
Medium Speed Supply Air Flow Ratio
number 0.66 Medium Speed Supply Air Flow Ratio should be greater than Low Speed Supply Air Flow Ratio
Range: > 0
maximum_outdoor_air_flow_rate
Maximum Outdoor Air Flow Rate required
number or Autosize
m3/s
outdoor_air_schedule_name
Outdoor Air Schedule Name
reference Value of schedule multiplies maximum outdoor air flow rate
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
air_inlet_node_name
Air Inlet Node Name required
string
air_outlet_node_name
Air Outlet Node Name required
string
outdoor_air_mixer_object_type
Outdoor Air Mixer Object Type
choice Currently only one type OutdoorAir:Mixer object is available. This field should be left blank if the FanCoil is connected to central dedicated outdoor air through an AirTerminal:SingleDuct:Mixer object.
One of OutdoorAir:Mixer
outdoor_air_mixer_name
Outdoor Air Mixer Name
reference If this field is blank, the OutdoorAir:Mixer is not used. This optional field specifies the name of the OutdoorAir:Mixer object. When used, this name needs to match name of the OutdoorAir:Mixer object. This field should be left blank if the FanCoil is connected to central dedicated outdoor air through an AirTerminal:SingleDuct:Mixer object.
Names a OutdoorAir:Mixer
supply_air_fan_object_type
Supply Air Fan Object Type required
choice Fan type must be according to capacity control method (see I/O) For ConstantFanVariableFlow a Fan:OnOff or Fan:ConstantVolume is valid. For CyclingFan a Fan:OnOff is valid. For VariableFanVariableFlow or VariableFanConstantFlow a Fan:VariableVolume is valid. For ASHRAE90.1 a Fan:OnOff or Fan:VariableVolume is valid. Fan:SystemModel is valid for all capacity control methods. The fan's inlet node should be the same as the outdoor air mixer's mixed air node.
One of Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel, Fan:VariableVolume
supply_air_fan_name
Supply Air Fan Name required
reference Names a Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel, Fan:VariableVolume
cooling_coil_object_type
Cooling Coil Object Type required
choice One of Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, CoilSystem:Cooling:Water:HeatExchangerAssisted
cooling_coil_name
Cooling Coil Name required
reference Names a Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, CoilSystem:Cooling:Water:HeatExchangerAssisted
maximum_cold_water_flow_rate
Maximum Cold Water Flow Rate required
number or Autosize
m3/s
minimum_cold_water_flow_rate
Minimum Cold Water Flow Rate
number
m3/s
0.0
cooling_convergence_tolerance
Cooling Convergence Tolerance
number 0.001 Range: > 0
heating_coil_object_type
Heating Coil Object Type required
choice One of Coil:Heating:Electric, Coil:Heating:Water
heating_coil_name
Heating Coil Name required
reference Names a Coil:Heating:Electric, Coil:Heating:Water
maximum_hot_water_flow_rate
Maximum Hot Water Flow Rate required
number or Autosize
m3/s
minimum_hot_water_flow_rate
Minimum Hot Water Flow Rate
number
m3/s
0.0
heating_convergence_tolerance
Heating Convergence Tolerance
number 0.001 Range: > 0
availability_manager_list_name
Availability Manager List Name
reference Enter the name of an AvailabilityManagerAssignmentList object.
Names a AvailabilityManagerAssignmentList
design_specification_zonehvac_sizing_object_name
Design Specification ZoneHVAC Sizing Object Name
reference Enter the name of a DesignSpecificationZoneHVACSizing object.
Names a DesignSpecification:ZoneHVAC:Sizing
supply_air_fan_operating_mode_schedule_name
Supply Air Fan Operating Mode Schedule Name
reference Enter the name of a schedule that controls fan operation. Schedule Name values of 0 denote cycling fan operation (fan cycles with cooling coil). Schedule values greater than 0 denote constant fan operation (fan runs continually regardless of coil operation). The fan operating mode defaults to cycling fan operation if this field is left blank. This input field is currently used with MultiStageFan capacity control method
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
minimum_supply_air_temperature_in_cooling_mode
Minimum Supply Air Temperature in Cooling Mode
number or Autosize
C
Autosize For Capacity Control Method = ASHRAE90VariableFan, enter the minimum air temperature in cooling mode. Leave this field blank or enter 0 to control to the zone load per ASHRAE 90.1. In this case, a zone sizing simulation is required.
maximum_supply_air_temperature_in_heating_mode
Maximum Supply Air Temperature in Heating Mode
number or Autosize
C
Autosize For Capacity Control Method = ASHRAE90VariableFan, enter the maximum air temperature in heating mode. Leave this field blank or enter 0 to control to the zone load per ASHRAE 90.1. In this case, a zone sizing simulation is required.
Referenced by 4 object types

AirTerminal:SingleDuct:Mixer, FaultModel:TemperatureSensorOffset:CoilSupplyAir, SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList

ZoneHVAC:HybridUnitaryHVAC

from idfpy.models import ZoneHVACHybridUnitaryHVAC extensible

Hybrid Unitary HVAC. A black box model for multi-mode packaged forced air equipment. Independent variables include outdoor air conditions and indoor air conditions. Controlled inputs include operating mode, supply air flow rate, and outdoor air faction. Empirical lookup tables are required to map supply air temperature supply air humidity, electricity use, fuel uses, water use, fan electricity use, and external static pressure as a function of each independent variable and each controlled input. In each timestep the model will choose one or more combinations of settings for mode, supply air flow rate, outdoor air faction, and part runtime fraction so as to satisfy zone requests for sensible cooling, heating, ventilation, and/or dehumidification with the least resource consumption. Equipment in this class may consume electricity, water, and up to two additional fuel types.

Field Type Default Details
name
Name required
string
availability_schedule_name
Availability Schedule Name
reference Enter the availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
availability_manager_list_name
Availability Manager List Name
reference Enter the name of an AvailabilityManagerAssignmentList object.
Names a AvailabilityManagerAssignmentList
minimum_supply_air_temperature_schedule_name
Minimum Supply Air Temperature Schedule Name
reference Values in this schedule are used as a constraint in choosing the feasible settings for supply air flow rate and outside air fraction in each operating mode. If this field is blank, no minimum is imposed.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
maximum_supply_air_temperature_schedule_name
Maximum Supply Air Temperature Schedule Name
reference Values in this schedule are used as a constraint in choosing the feasible settings for supply air flow rate and outdoor air fraction in each operating mode. If this field is blank, no maximum is imposed.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
minimum_supply_air_humidity_ratio_schedule_name
Minimum Supply Air Humidity Ratio Schedule Name
reference Values in this schedule are used as a constraint in choosing the feasible settings for supply air flow rate and outdoor air fraction in each operating mode. If this field is blank, no minimum is imposed.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
maximum_supply_air_humidity_ratio_schedule_name
Maximum Supply Air Humidity Ratio Schedule Name
reference Values in this schedule are used as a constraint in choosing the feasible settings for supply air flow rate and outdoor air fraction in each operating mode. If this field is blank, no maximum is imposed.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
method_to_choose_controlled_inputs_and_part_runtime_fraction
Method to Choose Controlled Inputs and Part Runtime Fraction
choice Automatic Select the method that will be used to choose operating mode(s), supply air flow rate(s), outdoor air fraction(s) and part runtime fraction(s) in each time step. "Automatic" = chooses controlled inputs and part runtime fraction(s) to minimize resource use within each time step while best satisfying requested sensible cooling, dehumidification and ventilation, and subject to constraints. "User Defined" = EMS will be used to choose controlled inputs and part runtime fraction(s) in each time step. If this field is blank, default to "Automatic".
One of Automatic, User Defined
return_air_node_name
Return Air Node Name required
string Return air node for the hybrid unit must be a zone exhaust node.
outdoor_air_node_name
Outdoor Air Node Name required
string Outdoor air node for the hybrid unit must be an outdoor air node.
supply_air_node_name
Supply Air Node Name required
string Supply air node for the hybrid unit must be a zone air inlet node.
relief_node_name
Relief Node Name
string Relief node for the hybrid unit must be a zone exhaust node, unless flow is being balanced elsewhere.
system_maximum_supply_air_flow_rate
System Maximum Supply Air Flow Rate
number
m3/s
The value in this field represents the maximum supply air volume flow rate among all operating modes. Values of extensive variables in lookup tables are normalized by the system maximum supply air mass flow rate that was used to build performance curves. The value in this field is used to rescale the output from extensive variables to a desired system size.
Range: > 0
external_static_pressure_at_system_maximum_supply_air_flow_rate
External Static Pressure at System Maximum Supply Air Flow Rate
number
Pa
Input the external static pressure when the system operates at maximum supply air flow rate. Fan affinity laws are used to scale supply fan power from the values tabulated in lookup tables, to values that match the external static pressure input to this field. If this field is blank, the supply fan power is not scaled from the values tabulated in lookup tables.
Range: > 0
fan_heat_included_in_lookup_tables
Fan Heat Included in Lookup Tables
choice No This field specifies if the fan heat is accounted for in the lookup tables.
One of No, Yes
fan_heat_gain_location
Fan Heat Gain Location
choice SupplyAirStream This field specifies where to add the fan heat in the air stream.
One of MixedAirStream, SupplyAirStream
fan_heat_in_air_stream_fraction
Fan Heat In Air Stream Fraction
number 1.0 0.0 means no fan heat is added to the air stream, 1.0 means all fan heat is added to the air stream.
Range: ≥ 0, ≤ 1
scaling_factor
Scaling Factor
number 1.0 The value in this field scales all extensive performance variables including: supply air mass flow rate, fuel uses, and water use. If this field is blank, the default scaling factor is 1.
Range: > 0
minimum_time_between_mode_change
Minimum Time Between Mode Change
number
minutes
10.0 Any mode selected will not operate for less time than the value input in this field. If the value in this field is larger than each timestep, the mode selected in one time step will persist in later time steps until the minimum time between mode change is satisfied. Supply air mass flow rate and outdoor air fraction within a mode are not subject to minimum runtime and may change in every time step. Mode 0 does not have a minimum time. If this field is blank, the default minimum time between mode change is 10 minutes.
Range: ≥ 1
first_fuel_type
First Fuel Type
choice Electricity Select the fuel type associated with field: "System Electric Power Lookup Table" in each mode. If this field is blank, default first fuel type = Electricity.
One of Coal, Diesel, DistrictCooling, DistrictHeatingSteam, DistrictHeatingWater, Electricity, FuelOilNo1, FuelOilNo2, Gasoline, NaturalGas, None, OtherFuel1, OtherFuel2, Propane
second_fuel_type
Second Fuel Type
choice None Select the fuel type associated with field: "System Second Fuel Consumption Lookup Table" in each mode. If this field is blank, default second fuel type = None.
One of Coal, Diesel, DistrictCooling, DistrictHeatingSteam, DistrictHeatingWater, Electricity, FuelOilNo1, FuelOilNo2, Gasoline, NaturalGas, None, OtherFuel1, OtherFuel2, Propane
third_fuel_type
Third Fuel Type
choice None Select the fuel type associated with field: "System Third Fuel Consumption Lookup Table" in each mode. If this field is blank, default third fuel type = None.
One of Coal, Diesel, DistrictCooling, DistrictHeatingSteam, DistrictHeatingWater, Electricity, FuelOilNo1, FuelOilNo2, Gasoline, NaturalGas, None, OtherFuel1, OtherFuel2, Propane
objective_function_to_minimize
Objective Function to Minimize
choice Electricity Use In each time step, controlled variables will be chosen to minimize the selection in this field, subject to constraints. If this field is blank, the objective function will minimize electricity use.
One of Electricity Use, Second Fuel Use, Third Fuel Use, Water Use
design_specification_outdoor_air_object_name
Design Specification Outdoor Air Object Name
reference Enter the name of a DesignSpecification:OutdoorAir object. Information in that object will be used to compute the minimum outdoor air flow rate in each time step. If this field is blank, the system may still supply outdoor air, if it is capable as described by lookup tables, when doing so is the most efficient way to satisfy other constraints.
Names a DesignSpecification:OutdoorAir, DesignSpecification:OutdoorAir:SpaceList
mode_0_name
Mode 0 Name
string Enter a name for Mode 0. Mode 0 describes equipment performance in standby. Mode 0 is usually characterized by electricity use for controls and crankcase heaters, or other standby resource consumption. Mode 0 will be chosen for any timestep, or portion of timestep, when no ventilation, cooling, humidification, or dehumidification is required. Mode 0 is available at any environmental condition.
mode_0_supply_air_temperature_lookup_table_name
Mode 0 Supply Air Temperature Lookup Table Name
reference Enter the name of the Supply Air Temperature Lookup Table for Mode 0. Units for lookup table values should be in C. If this field is blank, Mode 0 will not be considered for any period that requires ventilation, heating, cooling, humidification, or dehumidification. If this field is blank, when Mode 0 is chosen (during standby periods) the supply air temperature will equal the return air temperature.
Names a Table:Lookup
mode_0_supply_air_humidity_ratio_lookup_table_name
Mode 0 Supply Air Humidity Ratio Lookup Table Name
reference Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 0. Units for lookup table values should be in kgWater/kgDryAir. If this field is blank, Mode 0 will not be considered for any period that requires ventilation, heating, cooling, humidification, or dehumidification. If this field is blank, when Mode 0 is chosen (during standby periods) the supply air humidity ratio will equal the return air humidity ratio.
Names a Table:Lookup
mode_0_system_electric_power_lookup_table_name
Mode 0 System Electric Power Lookup Table Name
reference Enter the name of the Electric Power Lookup Table for Mode 0. Units for lookup table values should be in W. If this field is blank, Mode 0 does not consume electricity.
Names a Table:Lookup
mode_0_supply_fan_electric_power_lookup_table_name
Mode 0 Supply Fan Electric Power Lookup Table Name
reference Enter the name of the Supply Fan Electric Power Lookup Table for Mode 0. Units for lookup table values should be in W. If this field is blank, Mode 0 does not consume electricity for supply fan.
Names a Table:Lookup
mode_0_external_static_pressure_lookup_table_name
Mode 0 External Static Pressure Lookup Table Name
reference Enter the name of the External Static Pressure Lookup Table for Mode 0. Units for lookup table values should be in Pa. If this field is blank, external static pressure will not be reported.
Names a Table:Lookup
mode_0_system_second_fuel_consumption_lookup_table_name
Mode 0 System Second Fuel Consumption Lookup Table Name
reference Enter the name of the System Second Fuel Consumption Lookup Table for Mode 0. Units for lookup table values should be in W. If this field is blank, Mode 0 does not consume a second fuel.
Names a Table:Lookup
mode_0_system_third_fuel_consumption_lookup_table_name
Mode 0 System Third Fuel Consumption Lookup Table Name
reference Enter the name of the System Third Fuel Consumption Lookup Table for Mode 0. Units for lookup table values should be in W. If this field is blank, Mode 0 does not consume a third fuel.
Names a Table:Lookup
mode_0_system_water_use_lookup_table_name
Mode 0 System Water Use Lookup Table Name
reference Enter the name of the System Water Use Lookup Table for Mode 0. Units for lookup table values should be in kg/s. If this field is blank, Mode 0 does not consume water.
Names a Table:Lookup
mode_0_outdoor_air_fraction
Mode 0 Outdoor Air Fraction
number 0.0 Enter the outdoor air fraction for Mode 0. If this field is blank, the outdoor air fraction for Mode 0 will be 0.00.
Range: ≥ 0, ≤ 1
mode_0_supply_air_mass_flow_rate_ratio
Mode 0 Supply Air Mass Flow Rate Ratio
number 0.0 Enter the supply air mass flow rate ratio for Mode 0. The value in this field will be used to determine the supply air mass flow rate in Mode 0. Supply air mass flow rate ratio describes supply air mass flow rate as a fraction of mass flow rate associated with the value in field: "System Maximum Supply Air Flow Rate". If this field is blank, the supply air mass flow rate ratio for Mode 0 will be 0.
Range: ≥ 0, ≤ 1
modes list Each item: mode_name, mode_supply_air_temperature_lookup_table_name, mode_supply_air_humidity_ratio_lookup_table_name, mode_system_electric_power_lookup_table_name, mode_supply_fan_electric_power_lookup_table_name, mode_external_static_pressure_lookup_table_name, mode_system_second_fuel_consumption_lookup_table_name, mode_system_third_fuel_consumption_lookup_table_name, mode_system_water_use_lookup_table_name, mode_minimum_outdoor_air_temperature (C), mode_maximum_outdoor_air_temperature (C), mode_minimum_outdoor_air_humidity_ratio (kgWater/kgDryAir), mode_maximum_outdoor_air_humidity_ratio (kgWater/kgDryAir), mode_minimum_outdoor_air_relative_humidity (percent), mode_maximum_outdoor_air_relative_humidity (percent), mode_minimum_return_air_temperature (C), mode_maximum_return_air_temperature (C), mode_minimum_return_air_humidity_ratio (kgWater/kgDryAir), mode_maximum_return_air_humidity_ratio (kgWater/kgDryAir), mode_minimum_return_air_relative_humidity (percent), mode_maximum_return_air_relative_humidity (percent), mode_minimum_outdoor_air_fraction, mode_maximum_outdoor_air_fraction, mode_minimum_supply_air_mass_flow_rate_ratio, mode_maximum_supply_air_mass_flow_rate_ratio
Referenced by 2 object types

SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList

ZoneHVAC:IdealLoadsAirSystem

from idfpy.models import ZoneHVACIdealLoadsAirSystem

Ideal system used to calculate loads without modeling a full HVAC system. All that is required for the ideal system are zone controls, zone equipment configurations, and the ideal loads system component. This component can be thought of as an ideal unit that mixes zone air with the specified amount of outdoor air and then adds or removes heat and moisture at 100% efficiency in order to meet the specified controls. Energy use is reported as DistrictHeatingWater and DistrictCooling.

Field Type Default Details
name
Name required
string
availability_schedule_name
Availability Schedule Name
reference Availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
zone_supply_air_node_name
Zone Supply Air Node Name required
string Must match a zone air inlet node name.
zone_exhaust_air_node_name
Zone Exhaust Air Node Name
string Should match a zone air exhaust node name. This field is optional, but is required if this this object is used with other forced air equipment.
system_inlet_air_node_name
System Inlet Air Node Name
string This field is only required when the Ideal Loads Air System is connected to an AirloopHVAC:ZoneReturnPlenum, otherwise leave this field blank. When connected to a plenum the return plenum Outlet Node Name (or Induced Air Outlet Node Name when connecting multiple ideal loads air systems) is entered here. The two ideal loads air system node name fields described above, the Zone Supply Air Node Name and the Zone Exhaust Air Node Name must also be entered. The Zone Supply Air Node Name must match a zone inlet air node name for the zone where this Ideal Loads Air System is connected. The Zone Exhaust Air Node Name must match an inlet air node name of an AirloopHVAC:ReturnAirPlenum object.
maximum_heating_supply_air_temperature
Maximum Heating Supply Air Temperature
number
C
50.0 Range: > 0, < 100
minimum_cooling_supply_air_temperature
Minimum Cooling Supply Air Temperature
number
C
13.0 Range: > -100, < 50
maximum_heating_supply_air_humidity_ratio
Maximum Heating Supply Air Humidity Ratio
number
kgWater/kgDryAir
0.0156 Range: > 0
minimum_cooling_supply_air_humidity_ratio
Minimum Cooling Supply Air Humidity Ratio
number
kgWater/kgDryAir
0.0077 Range: > 0
heating_limit
Heating Limit
choice NoLimit One of LimitCapacity, LimitFlowRate, LimitFlowRateAndCapacity, NoLimit
maximum_heating_air_flow_rate
Maximum Heating Air Flow Rate
number or Autosize
m3/s
This field is ignored if Heating Limit = NoLimit If this field is blank, there is no limit.
maximum_sensible_heating_capacity
Maximum Sensible Heating Capacity
number or Autosize
W
This field is ignored if Heating Limit = NoLimit If this field is blank, there is no limit.
cooling_limit
Cooling Limit
choice NoLimit One of LimitCapacity, LimitFlowRate, LimitFlowRateAndCapacity, NoLimit
maximum_cooling_air_flow_rate
Maximum Cooling Air Flow Rate
number or Autosize
m3/s
This field is ignored if Cooling Limit = NoLimit This field is required if Outdoor Air Economizer Type is anything other than NoEconomizer.
maximum_total_cooling_capacity
Maximum Total Cooling Capacity
number or Autosize
W
This field is ignored if Cooling Limit = NoLimit
heating_availability_schedule_name
Heating Availability Schedule Name
reference If blank, heating is always available.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
cooling_availability_schedule_name
Cooling Availability Schedule Name
reference If blank, cooling is always available.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
dehumidification_control_type
Dehumidification Control Type
choice ConstantSensibleHeatRatio ConstantSensibleHeatRatio means that the ideal loads system will be controlled to meet the sensible cooling load, and the latent cooling rate will be computed using a constant sensible heat ratio (SHR) Humidistat means that there is a ZoneControl:Humidistat for this zone and the ideal loads system will attempt to satisfy the humidistat. None means that there is no dehumidification. ConstantSupplyHumidityRatio means that during cooling the supply air will always be at the Minimum Cooling Supply Humidity Ratio.
One of ConstantSensibleHeatRatio, ConstantSupplyHumidityRatio, Humidistat, None
cooling_sensible_heat_ratio
Cooling Sensible Heat Ratio
number
dimensionless
0.7 This field is applicable only when Dehumidification Control Type is ConstantSensibleHeatRatio
Range: > 0, ≤ 1
humidification_control_type
Humidification Control Type
choice None None means that there is no humidification. Humidistat means that there is a ZoneControl:Humidistat for this zone and the ideal loads system will attempt to satisfy the humidistat. ConstantSupplyHumidityRatio means that during heating the supply air will always be at the Maximum Heating Supply Humidity Ratio.
One of ConstantSupplyHumidityRatio, Humidistat, None
design_specification_outdoor_air_object_name
Design Specification Outdoor Air Object Name
reference When the name of a DesignSpecification:OutdoorAir object is entered, the minimum outdoor air flow rate will be computed using these specifications. The outdoor air flow rate will also be affected by the next two fields. If this field is blank, there will be no outdoor air and the remaining fields will be ignored.
Names a DesignSpecification:OutdoorAir, DesignSpecification:OutdoorAir:SpaceList
outdoor_air_inlet_node_name
Outdoor Air Inlet Node Name
string This field is required if the system provides outdoor air Enter the name of an outdoor air node. This node name is also specified in an OutdoorAir:Node or OutdoorAir:NodeList object.
demand_controlled_ventilation_type
Demand Controlled Ventilation Type
choice None This field controls how the minimum outdoor air flow rate is calculated. None means that design occupancy will be used to compute the minimum outdoor air flow rate OccupancySchedule means that current occupancy level will be used. CO2Setpoint means that the design occupancy will be used to compute the minimum outdoor air flow rate and the outdoor air flow rate may be increased if necessary to maintain the indoor air carbon dioxide setpoint defined in a ZoneControl:ContaminantController object.
One of CO2Setpoint, None, OccupancySchedule
outdoor_air_economizer_type
Outdoor Air Economizer Type
choice NoEconomizer DifferentialDryBulb and DifferentialEnthalpy will increase the outdoor air flow rate when there is a cooling load and the outdoor air temperature or enthalpy is below the zone exhaust air temperature or enthalpy.
One of DifferentialDryBulb, DifferentialEnthalpy, NoEconomizer
heat_recovery_type
Heat Recovery Type
choice None One of Enthalpy, None, Sensible
sensible_heat_recovery_effectiveness
Sensible Heat Recovery Effectiveness
number
dimensionless
0.7 Range: ≥ 0, ≤ 1
latent_heat_recovery_effectiveness
Latent Heat Recovery Effectiveness
number
dimensionless
0.65 Applicable only if Heat Recovery Type is Enthalpy.
Range: ≥ 0, ≤ 1
design_specification_zonehvac_sizing_object_name
Design Specification ZoneHVAC Sizing Object Name
reference Enter the name of a DesignSpecificationZoneHVACSizing object.
Names a DesignSpecification:ZoneHVAC:Sizing
heating_fuel_efficiency_schedule_name
Heating Fuel Efficiency Schedule Name
reference Reference heating fuel efficiency value for converting heating ideal loads into fuel energy consumption. The minimum schedule value must be greater than 0.0. The maximum value depends on the technology, and can exceed 1.0. If blank, heating fuel efficiency value is always 1.0.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
heating_fuel_type
Heating Fuel Type
choice DistrictHeatingWater One of Coal, Diesel, DistrictCooling, DistrictHeatingSteam, DistrictHeatingWater, Electricity, FuelOilNo1, FuelOilNo2, Gasoline, NaturalGas, OtherFuel1, OtherFuel2, Propane
cooling_fuel_efficiency_schedule_name
Cooling Fuel Efficiency Schedule Name
reference Reference cooling fuel efficiency value for converting cooling ideal loads into fuel energy consumption. The minimum schedule value must be greater than 0.0. The maximum value depends on the technology, and can exceed 1.0. If blank, cooling fuel efficiency value is always 1.0.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
cooling_fuel_type
Cooling Fuel Type
choice DistrictCooling One of Coal, Diesel, DistrictCooling, DistrictHeatingSteam, DistrictHeatingWater, Electricity, FuelOilNo1, FuelOilNo2, Gasoline, NaturalGas, OtherFuel1, OtherFuel2, Propane
Referenced by 2 object types

SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList

ZoneHVAC:OutdoorAirUnit

from idfpy.models import ZoneHVACOutdoorAirUnit

The zone outdoor air unit models a single-zone dedicated outdoor air system (DOAS). Forced-convection 100% outdoor air unit with supply fan and optional equipment including exhaust fan, heating coil, cooling coil, and heat recovery.

Field Type Default Details
name
Name required
string
availability_schedule_name
Availability Schedule Name
reference Availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
zone_name
Zone Name required
reference (name of zone system is serving)
Names a Zone
outdoor_air_flow_rate
Outdoor Air Flow Rate required
number or Autosize
m3/s
outdoor_air_schedule_name
Outdoor Air Schedule Name required
reference Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
supply_fan_name
Supply Fan Name required
reference Allowable fan types are Fan:SystemModel and Fan:ConstantVolume and Fan:VariableVolume
Names a Fan:ConstantVolume, Fan:SystemModel, Fan:VariableVolume
supply_fan_placement
Supply Fan Placement
choice DrawThrough One of BlowThrough, DrawThrough
exhaust_fan_name
Exhaust Fan Name
reference Allowable fan types are Fan:SystemModel and Fan:ConstantVolume and Fan:VariableVolume Fan:VariableVolume
Names a Fan:ConstantVolume, Fan:SystemModel, Fan:VariableVolume
exhaust_air_flow_rate
Exhaust Air Flow Rate
number or Autosize
m3/s
exhaust_air_schedule_name
Exhaust Air Schedule Name
reference Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
unit_control_type
Unit Control Type
choice NeutralControl One of NeutralControl, TemperatureControl
high_air_control_temperature_schedule_name
High Air Control Temperature Schedule Name
reference Air and control temperatures for cooling. If outdoor air temperature is above the high air control temperature, then the zone inlet air temperature is set to the high air control temperature. If the outdoor air is between high and low air control temperature, then there is no cooling/heating requirements.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
low_air_control_temperature_schedule_name
Low Air Control Temperature Schedule Name
reference Air and control temperatures for Heating. If outdoor air temperature is below the low air control temperature, then the zone inlet air temperature is set to the low air control temperature. If the outdoor air is between high and low air control temperature, then there is no cooling/heating requirements.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
outdoor_air_node_name
Outdoor Air Node Name required
string
airoutlet_node_name
AirOutlet Node Name required
string
airinlet_node_name
AirInlet Node Name
string air leaves zone
supply_fanoutlet_node_name
Supply FanOutlet Node Name required
string
outdoor_air_unit_list_name
Outdoor Air Unit List Name required
reference Enter the name of an ZoneHVAC:OutdoorAirUnit:EquipmentList object.
Names a ZoneHVAC:OutdoorAirUnit:EquipmentList
availability_manager_list_name
Availability Manager List Name
reference Enter the name of an AvailabilityManagerAssignmentList object.
Names a AvailabilityManagerAssignmentList
Referenced by 2 object types

SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList

ZoneHVAC:OutdoorAirUnit:EquipmentList

from idfpy.models import ZoneHVACOutdoorAirUnitEquipmentList

Equipment list for components in a ZoneHVAC:OutdoorAirUnit. Components are simulated sequentially in the order given in the equipment list.

Field Type Default Details
name
Name required
string
component_1_object_type
Component 1 Object Type
choice One of AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water:HeatexchangerAssisted, CoilSystem:Heating:DX, Dehumidifier:Desiccant:NoFans, HeatExchanger:AirToAir:FlatPlate, HeatExchanger:AirToAir:SensibleAndLatent
component_1_name
Component 1 Name
string
component_2_object_type
Component 2 Object Type
choice One of AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water:HeatexchangerAssisted, CoilSystem:Heating:DX, Dehumidifier:Desiccant:NoFans, HeatExchanger:AirToAir:FlatPlate, HeatExchanger:AirToAir:SensibleAndLatent
component_2_name
Component 2 Name
string
component_3_object_type
Component 3 Object Type
choice One of AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water:HeatexchangerAssisted, CoilSystem:Heating:DX, Dehumidifier:Desiccant:NoFans, HeatExchanger:AirToAir:FlatPlate, HeatExchanger:AirToAir:SensibleAndLatent
component_3_name
Component 3 Name
string
component_4_object_type
Component 4 Object Type
choice One of AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water:HeatexchangerAssisted, CoilSystem:Heating:DX, Dehumidifier:Desiccant:NoFans, HeatExchanger:AirToAir:FlatPlate, HeatExchanger:AirToAir:SensibleAndLatent
component_4_name
Component 4 Name
string
component_5_object_type
Component 5 Object Type
choice One of AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water:HeatexchangerAssisted, CoilSystem:Heating:DX, Dehumidifier:Desiccant:NoFans, HeatExchanger:AirToAir:FlatPlate, HeatExchanger:AirToAir:SensibleAndLatent
component_5_name
Component 5 Name
string
component_6_object_type
Component 6 Object Type
choice One of AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water:HeatexchangerAssisted, CoilSystem:Heating:DX, Dehumidifier:Desiccant:NoFans, HeatExchanger:AirToAir:FlatPlate, HeatExchanger:AirToAir:SensibleAndLatent
component_6_name
Component 6 Name
string
component_7_object_type
Component 7 Object Type
choice One of AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water:HeatexchangerAssisted, CoilSystem:Heating:DX, Dehumidifier:Desiccant:NoFans, HeatExchanger:AirToAir:FlatPlate, HeatExchanger:AirToAir:SensibleAndLatent
component_7_name
Component 7 Name
string
component_8_object_type
Component 8 Object Type
choice One of AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water:HeatexchangerAssisted, CoilSystem:Heating:DX, Dehumidifier:Desiccant:NoFans, HeatExchanger:AirToAir:FlatPlate, HeatExchanger:AirToAir:SensibleAndLatent
component_8_name
Component 8 Name
string
Referenced by 1 object types

ZoneHVAC:OutdoorAirUnit

ZoneHVAC:PackagedTerminalAirConditioner

from idfpy.models import ZoneHVACPackagedTerminalAirConditioner

Packaged terminal air conditioner (PTAC). Forced-convection heating-cooling unit with supply fan, direct expansion (DX) cooling coil, heating coil (gas, electric, hot water, or steam) and fixed-position outdoor air mixer.

Field Type Default Details
name
Name required
string Unique name for this packaged terminal air conditioner object.
availability_schedule_name
Availability Schedule Name
reference Availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available. Schedule values of 0 denote the unit is off.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
air_inlet_node_name
Air Inlet Node Name required
string Air inlet node for the PTAC must be a zone air exhaust Node.
air_outlet_node_name
Air Outlet Node Name required
string Air outlet node for the PTAC must be a zone air inlet node.
outdoor_air_mixer_object_type
Outdoor Air Mixer Object Type
choice Currently only one OutdoorAir:Mixer object type is available. This field should be left blank if the PTAC is connected to central dedicated outdoor air through an AirTerminal:SingleDuct:Mixer object.
One of OutdoorAir:Mixer
outdoor_air_mixer_name
Outdoor Air Mixer Name
reference If this field is blank, the OutdoorAir:Mixer is not used. This optional field specifies the name of the OutdoorAir:Mixer object. When used, this name needs to match name of the OutdoorAir:Mixer object. This field should be left blank if the PTAC is connected to central dedicated outdoor air through an AirTerminal:SingleDuct:Mixer object.
Names a OutdoorAir:Mixer
cooling_supply_air_flow_rate
Cooling Supply Air Flow Rate required
number or Autosize
m3/s
Must be less than or equal to fan size.
heating_supply_air_flow_rate
Heating Supply Air Flow Rate required
number or Autosize
m3/s
Must be less than or equal to fan size.
no_load_supply_air_flow_rate
No Load Supply Air Flow Rate
number or Autosize
m3/s
Must be less than or equal to fan size. Only used when supply air fan operating mode schedule values specify continuous fan (schedule values greater than 0 specify continuous fan operation). This air flow rate is used when no heating or cooling is required and the cooling or heating coil is off. If this field is left blank or zero, the supply air flow rate from the previous on cycle (either cooling or heating) is used.
no_load_supply_air_flow_rate_control_set_to_low_speed
No Load Supply Air Flow Rate Control Set To Low Speed
choice Yes When Yes is selected the minimum air flow rate is used. When No is selected the maximum air flow rate is used.
One of No, Yes
cooling_outdoor_air_flow_rate
Cooling Outdoor Air Flow Rate required
number or Autosize
m3/s
Must be less than or equal to supply air flow rate during cooling operation. This field is set to zero flow when the PTAC is connected to central dedicated outdoor air through air terminal single duct mixer object.
heating_outdoor_air_flow_rate
Heating Outdoor Air Flow Rate required
number or Autosize
m3/s
Must be less than or equal to supply air flow rate during heating operation. This field is set to zero flow when the PTAC is connected to central dedicated outdoor air through air terminal single duct mixer object.
no_load_outdoor_air_flow_rate
No Load Outdoor Air Flow Rate
number or Autosize
m3/s
Only used when supply air fan operating mode schedule values specify continuous fan (schedule values greater than 0 specify continuous fan operation). This air flow rate is used when no heating or cooling is required and the cooling or heating coil is off. If this field is left blank or zero, the outdoor air flow rate from the previous on cycle (either cooling or heating) is used. This field is set to zero flow when the PTAC is connected to central dedicated outdoor air through air terminal single duct mixer object.
supply_air_fan_object_type
Supply Air Fan Object Type required
choice Fan:ConstantVolume only works when continuous fan operation is used the entire simulation (all supply air fan operating mode schedule values are greater than 0). If any fan operating mode schedule values are 0 a Fan:SystemModel or Fan:OnOff object must be used.
One of Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel
supply_air_fan_name
Supply Air Fan Name required
reference Needs to match in the fan object.
Names a Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel
heating_coil_object_type
Heating Coil Object Type required
choice Select the type of heating coil.
One of Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water
heating_coil_name
Heating Coil Name required
reference Needs to match in the heating coil object.
Names a Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water
cooling_coil_object_type
Cooling Coil Object Type required
choice Select the type of Cooling Coil. Only works with Coil:Cooling:DX or Coil:Cooling:DX:SingleSpeed or CoilSystem:Cooling:DX:HeatExchangerAssisted or Coil:Cooling:DX:VariableSpeed.
One of Coil:Cooling:DX, Coil:Cooling:DX:SingleSpeed, Coil:Cooling:DX:VariableSpeed, CoilSystem:Cooling:DX:HeatExchangerAssisted
cooling_coil_name
Cooling Coil Name required
reference Needs to match a DX cooling coil object.
Names a Coil:Cooling:DX, Coil:Cooling:DX:SingleSpeed, Coil:Cooling:DX:SingleSpeed:ThermalStorage, Coil:Cooling:DX:VariableSpeed, CoilSystem:Cooling:DX:HeatExchangerAssisted
fan_placement
Fan Placement
choice DrawThrough Select fan placement as either blow through or draw through.
One of BlowThrough, DrawThrough
supply_air_fan_operating_mode_schedule_name
Supply Air Fan Operating Mode Schedule Name
reference Enter the name of a schedule that controls fan operation. Schedule Name values of 0 denote cycling fan operation (fan cycles with cooling or heating coil). Schedule Name values greater than 0 denote constant fan operation (fan runs continually regardless of coil operation).
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
availability_manager_list_name
Availability Manager List Name
reference Enter the name of an AvailabilityManagerAssignmentList object.
Names a AvailabilityManagerAssignmentList
design_specification_zonehvac_sizing_object_name
Design Specification ZoneHVAC Sizing Object Name
reference Enter the name of a DesignSpecificationZoneHVACSizing object.
Names a DesignSpecification:ZoneHVAC:Sizing
capacity_control_method
Capacity Control Method
choice None One of None, SingleZoneVAV
minimum_supply_air_temperature_in_cooling_mode
Minimum Supply Air Temperature in Cooling Mode
number or Autosize
C
Autosize For Capacity Control Method = SingleZoneVAV, enter the minimum air temperature limit for reduced fan speed.
maximum_supply_air_temperature_in_heating_mode
Maximum Supply Air Temperature in Heating Mode
number or Autosize
C
Autosize For Capacity Control Method = SingleZoneVAV, enter the maximum air temperature limit for reduced fan speed.
Referenced by 4 object types

AirTerminal:SingleDuct:Mixer, FaultModel:TemperatureSensorOffset:CoilSupplyAir, SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList

ZoneHVAC:PackagedTerminalHeatPump

from idfpy.models import ZoneHVACPackagedTerminalHeatPump

Packaged terminal heat pump (PTHP). Forced-convection heating-cooling unit with supply fan, direct expansion (DX) cooling coil, DX heating coil (air-to-air heat pump), supplemental heating coil (gas, electric, hot water, or steam), and fixed-position outdoor air mixer.

Field Type Default Details
name
Name required
string Unique name for this packaged terminal heat pump object.
availability_schedule_name
Availability Schedule Name
reference Availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available. Schedule values of 0 denote the unit is off.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
air_inlet_node_name
Air Inlet Node Name required
string Air inlet node for the PTHP must be a zone air exhaust node.
air_outlet_node_name
Air Outlet Node Name required
string Air outlet node for the PTHP must be a zone air inlet node.
outdoor_air_mixer_object_type
Outdoor Air Mixer Object Type
choice Currently only one OutdoorAir:Mixer object type is available. This field should be left blank if the PTHP is connected to central dedicated outdoor air through an AirTerminal:SingleDuct:Mixer object.
One of OutdoorAir:Mixer
outdoor_air_mixer_name
Outdoor Air Mixer Name
reference If this field is blank, the OutdoorAir:Mixer is not used. This optional field specifies the name of the OutdoorAir:Mixer object. When used, this name needs to match name of the OutdoorAir:Mixer object. This field should be left blank if the PTHP is connected to central dedicated outdoor air through an AirTerminal:SingleDuct:Mixer object.
Names a OutdoorAir:Mixer
cooling_supply_air_flow_rate
Cooling Supply Air Flow Rate required
number or Autosize
m3/s
Must be less than or equal to fan size.
heating_supply_air_flow_rate
Heating Supply Air Flow Rate required
number or Autosize
m3/s
Must be less than or equal to fan size.
no_load_supply_air_flow_rate
No Load Supply Air Flow Rate
number or Autosize
m3/s
Must be less than or equal to fan size. Only used when heat pump fan operating mode is continuous. This air flow rate is used when no heating or cooling is required and the DX coil compressor is off. If this field is left blank or zero, the supply air flow rate from the previous on cycle (either cooling or heating) is used.
no_load_supply_air_flow_rate_control_set_to_low_speed
No Load Supply Air Flow Rate Control Set To Low Speed
choice Yes When Yes is selected the minimum air flow rate is used. When No is selected the maximum air flow rate is used.
One of No, Yes
cooling_outdoor_air_flow_rate
Cooling Outdoor Air Flow Rate required
number or Autosize
m3/s
Must be less than or equal to supply air flow rate during cooling operation. This field is set to zero flow when the PTHP is connected to central dedicated outdoor air through air terminal single duct mixer object.
heating_outdoor_air_flow_rate
Heating Outdoor Air Flow Rate required
number or Autosize
m3/s
Must be less than or equal to supply air flow rate during heating operation. This field is set to zero flow when the PTHP is connected to central dedicated outdoor air through air terminal single duct mixer object.
no_load_outdoor_air_flow_rate
No Load Outdoor Air Flow Rate
number or Autosize
m3/s
Only used when heat pump Fan operating mode is continuous. This air flow rate is used when no heating or cooling is required and the DX coil compressor is off. If this field is left blank or zero, the outdoor air flow rate from the previous on cycle (either cooling or heating) is used. This field is set to zero flow when the PTHP is connected to central dedicated outdoor air through air terminal single duct mixer object.
supply_air_fan_object_type
Supply Air Fan Object Type required
choice Fan:ConstantVolume only works with fan operating mode is continuous.
One of Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel
supply_air_fan_name
Supply Air Fan Name required
reference Needs to match a fan object.
Names a Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel
heating_coil_object_type
Heating Coil Object Type required
choice Only works with Coil:Heating:DX:SingleSpeed or Coil:Heating:DX:VariableSpeed.
One of Coil:Heating:DX:SingleSpeed, Coil:Heating:DX:VariableSpeed
heating_coil_name
Heating Coil Name required
reference Needs to match in the DX Heating Coil object.
Names a Coil:Heating:DX:SingleSpeed, Coil:Heating:DX:VariableRefrigerantFlow, Coil:Heating:DX:VariableSpeed
heating_convergence_tolerance
Heating Convergence Tolerance
number
dimensionless
0.001 Defines Heating convergence tolerance as a fraction of Heating load to be met.
Range: > 0
cooling_coil_object_type
Cooling Coil Object Type required
choice Only works with Coil:Cooling:DX or Coil:Cooling:DX:SingleSpeed or CoilSystem:Cooling:DX:HeatExchangerAssisted or Coil:Cooling:DX:VariableSpeed.
One of Coil:Cooling:DX, Coil:Cooling:DX:SingleSpeed, Coil:Cooling:DX:VariableSpeed, CoilSystem:Cooling:DX:HeatExchangerAssisted
cooling_coil_name
Cooling Coil Name required
reference Needs to match in the DX Cooling Coil object.
Names a Coil:Cooling:DX, Coil:Cooling:DX:SingleSpeed, Coil:Cooling:DX:SingleSpeed:ThermalStorage, Coil:Cooling:DX:VariableSpeed, CoilSystem:Cooling:DX:HeatExchangerAssisted
cooling_convergence_tolerance
Cooling Convergence Tolerance
number
dimensionless
0.001 Defines Cooling convergence tolerance as a fraction of the Cooling load to be met.
Range: > 0
supplemental_heating_coil_object_type
Supplemental Heating Coil Object Type required
choice works with gas, electric, hot water and steam heating coil.
One of Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water
supplemental_heating_coil_name
Supplemental Heating Coil Name required
reference Needs to match in the supplemental heating coil object.
Names a Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water
maximum_supply_air_temperature_from_supplemental_heater
Maximum Supply Air Temperature from Supplemental Heater required
number or Autosize
C
Supply air temperature from the supplemental heater will not exceed this value.
maximum_outdoor_dry_bulb_temperature_for_supplemental_heater_operation
Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation
number
C
21.0 Supplemental heater will not operate when outdoor temperature exceeds this value.
Range: ≤ 21
fan_placement
Fan Placement
choice DrawThrough Select fan placement as either blow through or draw through.
One of BlowThrough, DrawThrough
supply_air_fan_operating_mode_schedule_name
Supply Air Fan Operating Mode Schedule Name
reference Enter the name of a schedule that controls fan operation. Schedule values of 0 denote cycling fan operation (fan cycles with cooling or heating coil). Schedule Name values greater than 0 denote constant fan operation (fan runs continually regardless of coil operation). The fan operating mode defaults to cycling fan operation if this field is left blank.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
availability_manager_list_name
Availability Manager List Name
reference Enter the name of an AvailabilityManagerAssignmentList object.
Names a AvailabilityManagerAssignmentList
design_specification_zonehvac_sizing_object_name
Design Specification ZoneHVAC Sizing Object Name
reference Enter the name of a DesignSpecificationZoneHVACSizing object.
Names a DesignSpecification:ZoneHVAC:Sizing
capacity_control_method
Capacity Control Method
choice None One of None, SingleZoneVAV
minimum_supply_air_temperature_in_cooling_mode
Minimum Supply Air Temperature in Cooling Mode
number or Autosize
C
Autosize For Capacity Control Method = SingleZoneVAV, enter the minimum air temperature limit for reduced fan speed.
maximum_supply_air_temperature_in_heating_mode
Maximum Supply Air Temperature in Heating Mode
number or Autosize
C
Autosize For Capacity Control Method = SingleZoneVAV, enter the maximum air temperature limit for reduced fan speed.
dx_heating_coil_sizing_ratio
DX Heating Coil Sizing Ratio
number 1.0 Used to adjust heat pump heating capacity with respect to DX cooling capacity used only for heat pump configurations (i.e., a DX cooling and DX heating coil is used).
Range: > 0
Referenced by 4 object types

AirTerminal:SingleDuct:Mixer, FaultModel:TemperatureSensorOffset:CoilSupplyAir, SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList

ZoneHVAC:TerminalUnit:VariableRefrigerantFlow

from idfpy.models import ZoneHVACTerminalUnitVariableRefrigerantFlow

A terminal unit with variable refrigerant flow (VRF) DX cooling and heating coils (air-to-air heat pump). The VRF terminal units are served by an AirConditioner:VariableRefrigerantFlow or AirConditioner:VariableRefrigerantFlow:FluidTemperatureControl:* system. Terminal units can be configured as zone, air loop or outside air system equipment.

Field Type Default Details
name
Zone Terminal Unit Name
string
terminal_unit_availability_schedule
Terminal Unit Availability Schedule
reference The unit is available the entire simulation if this field is left blank Schedule values of 0 denote the unit is off.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
terminal_unit_air_inlet_node_name
Terminal Unit Air Inlet Node Name required
string the inlet node to the terminal unit
terminal_unit_air_outlet_node_name
Terminal Unit Air Outlet Node Name required
string the outlet node of the terminal unit
cooling_supply_air_flow_rate
Cooling Supply Air Flow Rate
number or Autosize
m3/s
no_cooling_supply_air_flow_rate
No Cooling Supply Air Flow Rate
number or Autosize
m3/s
heating_supply_air_flow_rate
Heating Supply Air Flow Rate
number or Autosize
m3/s
no_heating_supply_air_flow_rate
No Heating Supply Air Flow Rate
number or Autosize
m3/s
cooling_outdoor_air_flow_rate
Cooling Outdoor Air Flow Rate
number or Autosize
m3/s
This field is used only when an outdoor air mixer is included. This field is set to zero flow when the VRF terminal unit is connected to central dedicated outdoor air through air terminal single duct mixer object. When this VRF terminal is used as air loop equipment the autosized flow rate will be set to 0 when an outdoor air system is connected to this air loop, otherwise the outdoor air flow rate will equal the maximum outdoor air flow rate.
heating_outdoor_air_flow_rate
Heating Outdoor Air Flow Rate
number or Autosize
m3/s
This field is used only when an outdoor air mixer is included. This field is set to zero flow when the VRF terminal unit is connected to central dedicated outdoor air through air terminal single duct mixer object. When this VRF terminal is used as air loop equipment the autosized flow rate will be set to 0 when an outdoor air system is connected to this air loop, otherwise the outdoor air flow rate will equal the maximum outdoor air flow rate.
no_load_outdoor_air_flow_rate
No Load Outdoor Air Flow Rate
number or Autosize
m3/s
This field is used only when an outdoor air mixer is included. This field is set to zero flow when the VRF terminal unit is connected to central dedicated outdoor air through air terminal single duct mixer object. When this VRF terminal is used as air loop equipment the autosized flow rate will be set to 0 when an outdoor air system is connected to this air loop, otherwise the outdoor air flow rate will equal the maximum outdoor air flow rate.
supply_air_fan_operating_mode_schedule_name
Supply Air Fan Operating Mode Schedule Name
reference Required for zone equipment. Leave blank if terminal unit is used in AirLoopHVAC:OutdoorAirSystem:EquipmentList. Also leave blank if terminal unit is used on main AirloopHVAC branch and terminal unit has no fan.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
supply_air_fan_placement
Supply Air Fan Placement
choice BlowThrough Select fan placement as either blow through or draw through. Required for zone equipment. This field is ignored if the VRF terminal unit is used in AirLoopHVAC:OutdoorAirSystem:EquipmentList. This field is also ignored if VRF terminal unit is used on main AirloopHVAC branch and terminal unit has no fan.
One of BlowThrough, DrawThrough
supply_air_fan_object_type
Supply Air Fan Object Type
choice Fan:ConstantVolume Supply Air Fan Object Type must be Fan:SystemModel, Fan:OnOff, or Fan:ConstantVolume if AirConditioner:VariableRefrigerantFlow is used to model VRF outdoor unit Supply Air Fan Object Type must be Fan:SystemModel if AirConditioner:VariableRefrigerantFlow:FluidTemperatureControl or AirConditioner:VariableRefrigerantFlow:FluidTemperatureControl:HR is used to model VRF outdoor unit Required for zone equipment. Leave blank if terminal unit is used in AirLoopHVAC:OutdoorAirSystem:EquipmentList. Also leave blank if terminal unit is used on main AirloopHVAC branch and terminal unit has no fan.
One of Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel
supply_air_fan_object_name
Supply Air Fan Object Name
reference Names a Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel, Fan:VariableVolume
outside_air_mixer_object_type
Outside Air Mixer Object Type
choice Currently only one type OutdoorAir:Mixer object is available. If this field is blank, and outside air mixer is not used. This field should be left blank if the VRF terminal unit is connected to central dedicated outdoor air through an AirTerminal:SingleDuct:Mixer object. This field may also be left blank when the VRF terminal is used in the air loop or outdoor air system.
One of OutdoorAir:Mixer
outside_air_mixer_object_name
Outside Air Mixer Object Name
reference If this field is blank, the OutdoorAir:Mixer is not used. This optional field specifies the name of the OutdoorAir:Mixer object. When used, this name needs to match name of the OutdoorAir:Mixer object. This field should be left blank if the VRF terminal unit is connected to central dedicated outdoor air through an AirTerminal:SingleDuct:Mixer object. This field may also be left blank when the VRF terminal is used in the air loop or outdoor air system.
Names a OutdoorAir:Mixer
cooling_coil_object_type
Cooling Coil Object Type
choice Cooling Coil Type must be Coil:Cooling:DX:VariableRefrigerantFlow if AirConditioner:VariableRefrigerantFlow is used to model VRF outdoor unit Cooling Coil Type must be Coil:Cooling:DX:VariableRefrigerantFlow:FluidTemperatureControl if AirConditioner:VariableRefrigerantFlow:FluidTemperatureControl or if AirConditioner:VariableRefrigerantFlow:FluidTemperatureControl:HR is used to model VRF outdoor unit This field may be left blank if heating-only mode is used
One of Coil:Cooling:DX:VariableRefrigerantFlow, Coil:Cooling:DX:VariableRefrigerantFlow:FluidTemperatureControl
cooling_coil_object_name
Cooling Coil Object Name
reference Cooling Coil Type must be Coil:Cooling:DX:VariableRefrigerantFlow This field may be left blank if heating-only mode is used
Names a Coil:Cooling:DX:VariableRefrigerantFlow, Coil:Cooling:DX:VariableRefrigerantFlow:FluidTemperatureControl
heating_coil_object_type
Heating Coil Object Type
choice Heating Coil Type must be Coil:Heating:DX:VariableRefrigerantFlow if AirConditioner:VariableRefrigerantFlow is used to model VRF outdoor unit Heating Coil Type must be Coil:Heating:DX:VariableRefrigerantFlow:FluidTemperatureControl if AirConditioner:VariableRefrigerantFlow:FluidTemperatureControl or if AirConditioner:VariableRefrigerantFlow:FluidTemperatureControl:HR is used to model VRF outdoor unit This field may be left blank if cooling-only mode is used
One of Coil:Heating:DX:VariableRefrigerantFlow, Coil:Heating:DX:VariableRefrigerantFlow:FluidTemperatureControl
heating_coil_object_name
Heating Coil Object Name
reference Heating Coil Type must be Coil:Heating:DX:VariableRefrigerantFlow This field may be left blank if cooling-only mode is used
Names a Coil:Heating:DX:VariableRefrigerantFlow, Coil:Heating:DX:VariableRefrigerantFlow:FluidTemperatureControl
zone_terminal_unit_on_parasitic_electric_energy_use
Zone Terminal Unit On Parasitic Electric Energy Use
number
W
0.0 Range: ≥ 0
zone_terminal_unit_off_parasitic_electric_energy_use
Zone Terminal Unit Off Parasitic Electric Energy Use
number
W
0.0 Range: ≥ 0
rated_heating_capacity_sizing_ratio
Rated Heating Capacity Sizing Ratio
number
W/W
1.0 If this terminal unit's heating coil is autosized, the heating capacity is sized to be equal to the cooling capacity multiplied by this sizing ratio. This input applies to the terminal unit heating coil and overrides the sizing ratio entered in the AirConditioner:VariableRefrigerantFlow object.
Range: ≥ 1
availability_manager_list_name
Availability Manager List Name
reference Enter the name of an AvailabilityManagerAssignmentList object.
Names a AvailabilityManagerAssignmentList
design_specification_zonehvac_sizing_object_name
Design Specification ZoneHVAC Sizing Object Name
reference Enter the name of a DesignSpecificationZoneHVACSizing object.
Names a DesignSpecification:ZoneHVAC:Sizing
supplemental_heating_coil_object_type
Supplemental Heating Coil Object Type
choice works with gas, electric, hot water and steam heating coil.
One of Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water
supplemental_heating_coil_name
Supplemental Heating Coil Name
reference Needs to match in the supplemental heating coil object.
Names a Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water
maximum_supply_air_temperature_from_supplemental_heater
Maximum Supply Air Temperature from Supplemental Heater
number or Autosize
C
Autosize Supply air temperature from the supplemental heater will not exceed this value.
maximum_outdoor_dry_bulb_temperature_for_supplemental_heater_operation
Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation
number
C
21.0 Supplemental heater will not operate when outdoor temperature exceeds this value.
Range: ≤ 21
controlling_zone_or_thermostat_location
Controlling Zone or Thermostat Location
reference Used only for AirloopHVAC equipment on a main branch and defines zone name where thermostat is located. Not required for zone equipment. Leave blank if terminal unit is used in AirLoopHVAC:OutdoorAirSystem:EquipmentList. Required when terminal unit is used on main AirloopHVAC branch and coils are not set point controlled. When terminal unit is used in air loop and is load controlled, this zone's thermostat will control operation.
Names a Zone
design_specification_multispeed_object_type
Design Specification Multispeed Object Type
choice Enter the type of performance specification object used to describe the multispeed coil or fan.
One of UnitarySystemPerformance:Multispeed
design_specification_multispeed_object_name
Design Specification Multispeed Object Name
reference The name of the performance specification object used to describe the multispeed coil or fan.
Names a UnitarySystemPerformance:Multispeed
Referenced by 8 object types

AirLoopHVAC:DedicatedOutdoorAirSystem, AirLoopHVAC:OutdoorAirSystem:EquipmentList, AirTerminal:SingleDuct:Mixer, Branch, FaultModel:TemperatureSensorOffset:CoilSupplyAir, SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList, ZoneTerminalUnitList

ZoneHVAC:UnitHeater

from idfpy.models import ZoneHVACUnitHeater

Unit heater. Forced-convection heating-only unit with supply fan, heating coil (gas, electric, hot water, or steam) and fixed-position outdoor air mixer.

Field Type Default Details
name
Name required
string
availability_schedule_name
Availability Schedule Name
reference Availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
air_inlet_node_name
Air Inlet Node Name
string
air_outlet_node_name
Air Outlet Node Name
string
supply_air_fan_object_type
Supply Air Fan Object Type required
choice Allowable fan types are Fan:ConstantVolume, Fan:OnOff, Fan:VariableVolume and Fan:SystemModel
One of Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel, Fan:VariableVolume
supply_air_fan_name
Supply Air Fan Name required
reference Names a Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel, Fan:VariableVolume
maximum_supply_air_flow_rate
Maximum Supply Air Flow Rate required
number or Autosize
m3/s
heating_coil_object_type
Heating Coil Object Type required
choice One of Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water
heating_coil_name
Heating Coil Name required
reference Names a Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water
supply_air_fan_operating_mode_schedule_name
Supply Air Fan Operating Mode Schedule Name
reference Enter the name of a schedule that controls fan operation. Schedule name values of 0 denote cycling fan operation (fan cycles with the heating coil). Schedule values greater than 0 denote constant fan operation (fan runs continually regardless of coil operation). The fan operating mode defaults to cycling fan operation if this input field is left blank.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
supply_air_fan_operation_during_no_heating
Supply Air Fan Operation During No Heating required
choice This choice field allows the user to define how the unit heater will operate under "no heating load" or cooling conditions. If the "No" is selected, then the fan will not run unless there is a heating load. If the fan does not run, this effectively shuts the unit heater system off when there is no heating load. If the "Yes" is selected, the unit heater is available and has a ConstantVolume fan, or has an OnOff fan with "Supply Air Fan Operating Mode Schedule" value greater than zero, then the fan will always run regardless of the zone load.
One of No, Yes
maximum_hot_water_or_steam_flow_rate
Maximum Hot Water or Steam Flow Rate
number or Autosize
m3/s
Not used when heating coil is gas or electric
minimum_hot_water_or_steam_flow_rate
Minimum Hot Water or Steam Flow Rate
number
m3/s
0.0 Not used when heating coil is gas or electric
Range: ≥ 0
heating_convergence_tolerance
Heating Convergence Tolerance
number 0.001 Range: > 0
availability_manager_list_name
Availability Manager List Name
reference Enter the name of an AvailabilityManagerAssignmentList object.
Names a AvailabilityManagerAssignmentList
design_specification_zonehvac_sizing_object_name
Design Specification ZoneHVAC Sizing Object Name
reference Enter the name of a DesignSpecificationZoneHVACSizing object.
Names a DesignSpecification:ZoneHVAC:Sizing
Referenced by 2 object types

SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList

ZoneHVAC:UnitVentilator

from idfpy.models import ZoneHVACUnitVentilator

Unit ventilator. Forced-convection ventilation unit with supply fan (constant-volume or variable-volume), optional chilled water cooling coil, optional heating coil (gas, electric, hot water, or steam) and controllable outdoor air mixer.

Field Type Default Details
name
Name required
string
availability_schedule_name
Availability Schedule Name
reference Availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
maximum_supply_air_flow_rate
Maximum Supply Air Flow Rate required
number or Autosize
m3/s
outdoor_air_control_type
Outdoor Air Control Type required
choice One of FixedAmount, FixedTemperature, VariablePercent
minimum_outdoor_air_flow_rate
Minimum Outdoor Air Flow Rate required
number or Autosize
m3/s
minimum_outdoor_air_schedule_name
Minimum Outdoor Air Schedule Name required
reference schedule values multiply the minimum outdoor air flow rate
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
maximum_outdoor_air_flow_rate
Maximum Outdoor Air Flow Rate required
number or Autosize
m3/s
maximum_outdoor_air_fraction_or_temperature_schedule_name
Maximum Outdoor Air Fraction or Temperature Schedule Name required
reference that this depends on the control type as to whether it is a fraction or temperature
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
air_inlet_node_name
Air Inlet Node Name required
string Inlet node name must be zone exhaust node name if there is no DOA Mixer, or if the unit ventilator is connected DOA, then the air inlet node name must be the mixer outlet air node name for InletSide mixer connection.
air_outlet_node_name
Air Outlet Node Name required
string Outlet node name must be zone inlet node name if there is no DOA Mixer, or if the unit ventilator is connected DOA, then the air outlet node name must be the mixer secondary air inlet node name for SupplySide mixer connection.
outdoor_air_node_name
Outdoor Air Node Name
string this field is left blank only if the Unit Ventilator is connected to a central dedicated outdoor air (DOA) via AirTerminal:SingleDuct:Mixer object
exhaust_air_node_name
Exhaust Air Node Name
string this field is left blank only if the Unit Ventilator is connected to a central dedicated outdoor air (DOA) via AirTerminal:SingleDuct:Mixer object
mixed_air_node_name
Mixed Air Node Name
string inlet to coils this field is left blank only if the Unit Ventilator is connected to a central dedicated outdoor air (DOA) via AirTerminal:SingleDuct:Mixer object
supply_air_fan_object_type
Supply Air Fan Object Type required
choice Allowable fan types are Fan:ConstantVolume, Fan:OnOff, Fan:VariableVolume, and Fan:SystemModel
One of Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel, Fan:VariableVolume
supply_air_fan_name
Supply Air Fan Name required
reference Names a Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel, Fan:VariableVolume
coil_option
Coil Option required
choice One of Cooling, Heating, HeatingAndCooling, None
supply_air_fan_operating_mode_schedule_name
Supply Air Fan Operating Mode Schedule Name
reference Enter the name of a schedule that controls fan operation. Schedule name values of 0 denote cycling fan operation (fan cycles with cooling/heating coil). Schedule values greater than 0 denote constant fan operation (fan runs continually regardless of coil operation). The fan operating mode defaults to cycling fan operation if this input field is left blank.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
heating_coil_object_type
Heating Coil Object Type
choice One of Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water
heating_coil_name
Heating Coil Name
reference Names a Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water
heating_convergence_tolerance
Heating Convergence Tolerance
number 0.001 Range: > 0
cooling_coil_object_type
Cooling Coil Object Type
choice One of Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, CoilSystem:Cooling:Water:HeatExchangerAssisted
cooling_coil_name
Cooling Coil Name
reference Names a Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, CoilSystem:Cooling:Water:HeatExchangerAssisted
cooling_convergence_tolerance
Cooling Convergence Tolerance
number 0.001 Range: > 0
availability_manager_list_name
Availability Manager List Name
reference Enter the name of an AvailabilityManagerAssignmentList object.
Names a AvailabilityManagerAssignmentList
design_specification_zonehvac_sizing_object_name
Design Specification ZoneHVAC Sizing Object Name
reference Enter the name of a DesignSpecificationZoneHVACSizing object.
Names a DesignSpecification:ZoneHVAC:Sizing
Referenced by 4 object types

AirTerminal:SingleDuct:Mixer, FaultModel:TemperatureSensorOffset:CoilSupplyAir, SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList

ZoneHVAC:WaterToAirHeatPump

from idfpy.models import ZoneHVACWaterToAirHeatPump

Water-to-air heat pump. Forced-convection heating-cooling unit with supply fan, water-to-air cooling and heating coils, supplemental heating coil (gas, electric, hot water, or steam), and fixed-position outdoor air mixer.

Field Type Default Details
name
Name required
string
availability_schedule_name
Availability Schedule Name
reference Availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
air_inlet_node_name
Air Inlet Node Name required
string
air_outlet_node_name
Air Outlet Node Name required
string
outdoor_air_mixer_object_type
Outdoor Air Mixer Object Type
choice Currently only one OutdoorAir:Mixer object type is available. This field should be left blank if the WSHP is connected to central dedicated outdoor air through an AirTerminal:SingleDuct:Mixer object.
One of OutdoorAir:Mixer
outdoor_air_mixer_name
Outdoor Air Mixer Name
reference If this field is blank, the OutdoorAir:Mixer is not used. This optional field specifies the name of the OutdoorAir:Mixer object. When used, this name needs to match name of the OutdoorAir:Mixer object. This field should be left blank if the WSHP is connected to central dedicated outdoor air through an AirTerminal:SingleDuct:Mixer object.
Names a OutdoorAir:Mixer
cooling_supply_air_flow_rate
Cooling Supply Air Flow Rate required
number or Autosize
m3/s
Must be less than or equal to fan size.
heating_supply_air_flow_rate
Heating Supply Air Flow Rate required
number or Autosize
m3/s
Must be less than or equal to fan size.
no_load_supply_air_flow_rate
No Load Supply Air Flow Rate
number or Autosize
m3/s
Must be less than or equal to fan size. Only used when heat pump fan operating mode is continuous. This air flow rate is used when no heating or cooling is required and the DX coil compressor is off. If this field is left blank or zero, the supply air flow rate from the previous on cycle (either cooling or heating) is used.
no_load_supply_air_flow_rate_control_set_to_low_speed
No Load Supply Air Flow Rate Control Set To Low Speed
choice Yes When Yes is selected the minimum air flow rate is used. When No is selected the maximum air flow rate is used.
One of No, Yes
cooling_outdoor_air_flow_rate
Cooling Outdoor Air Flow Rate required
number or Autosize
m3/s
Must be less than or equal to supply air flow rate during cooling operation. This field is set to zero flow when the WSHP is connected to central dedicated outdoor air through air terminal single duct mixer object.
heating_outdoor_air_flow_rate
Heating Outdoor Air Flow Rate required
number or Autosize
m3/s
Must be less than or equal to supply air flow rate during heating operation. This field is set to zero flow when the WSHP is connected to central dedicated outdoor air through air terminal single duct mixer object.
no_load_outdoor_air_flow_rate
No Load Outdoor Air Flow Rate
number or Autosize
m3/s
Only used when heat pump Fan operating mode is continuous. This air flow rate is used when no heating or cooling is required and the DX coil compressor is off. If this field is left blank or zero, the outdoor air flow rate from the previous on cycle (either cooling or heating) is used. This field is set to zero flow when the PTHP is connected to central dedicated outdoor air through air terminal single duct mixer object.
supply_air_fan_object_type
Supply Air Fan Object Type required
choice One of Fan:OnOff, Fan:SystemModel
supply_air_fan_name
Supply Air Fan Name required
reference Needs to match Fan:SystemModel or Fan:OnOff object
Names a Fan:OnOff, Fan:SystemModel
heating_coil_object_type
Heating Coil Object Type required
choice One of Coil:Heating:WaterToAirHeatPump:EquationFit, Coil:Heating:WaterToAirHeatPump:VariableSpeedEquationFit
heating_coil_name
Heating Coil Name required
reference Needs to match in the water-to-air heat pump heating coil object
Names a Coil:Heating:WaterToAirHeatPump:EquationFit, Coil:Heating:WaterToAirHeatPump:ParameterEstimation, Coil:Heating:WaterToAirHeatPump:VariableSpeedEquationFit
cooling_coil_object_type
Cooling Coil Object Type required
choice One of Coil:Cooling:WaterToAirHeatPump:EquationFit, Coil:Cooling:WaterToAirHeatPump:VariableSpeedEquationFit
cooling_coil_name
Cooling Coil Name required
reference Needs to match in the water-to-air heat pump cooling coil object
Names a Coil:Cooling:WaterToAirHeatPump:EquationFit, Coil:Cooling:WaterToAirHeatPump:ParameterEstimation, Coil:Cooling:WaterToAirHeatPump:VariableSpeedEquationFit
supplemental_heating_coil_object_type
Supplemental Heating Coil Object Type required
choice works with gas, electric, hot water and steam heating coils
One of Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water
supplemental_heating_coil_name
Supplemental Heating Coil Name required
reference Needs to match in the supplemental heating coil object
Names a Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water
maximum_supply_air_temperature_from_supplemental_heater
Maximum Supply Air Temperature from Supplemental Heater
number or Autosize
C
Autosize Supply air temperature from the supplemental heater will not exceed this value.
maximum_outdoor_dry_bulb_temperature_for_supplemental_heater_operation
Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation
number
C
21.0 Range: ≤ 21
outdoor_dry_bulb_temperature_sensor_node_name
Outdoor Dry-Bulb Temperature Sensor Node Name
string
fan_placement
Fan Placement
choice BlowThrough One of BlowThrough, DrawThrough
supply_air_fan_operating_mode_schedule_name
Supply Air Fan Operating Mode Schedule Name
reference Enter the name of a schedule that controls fan operation. Schedule values of 0 denote cycling fan operation (fan cycles with cooling or heating coil). Schedule values greater than 0 denote constant fan operation (fan runs continually regardless of coil operation). The fan operating mode defaults to cycling fan operation if this field is left blank.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
availability_manager_list_name
Availability Manager List Name
reference Enter the name of an AvailabilityManagerAssignmentList object.
Names a AvailabilityManagerAssignmentList
heat_pump_coil_water_flow_mode
Heat Pump Coil Water Flow Mode
choice Cycling used only when the heat pump coils are of the type WaterToAirHeatPump:EquationFit Constant results in 100% water flow regardless of compressor PLR Cycling results in water flow that matches compressor PLR ConstantOnDemand results in 100% water flow whenever the coil is on, but is 0% whenever the coil has no load
One of Constant, ConstantOnDemand, Cycling
design_specification_zonehvac_sizing_object_name
Design Specification ZoneHVAC Sizing Object Name
reference Enter the name of a DesignSpecificationZoneHVACSizing object.
Names a DesignSpecification:ZoneHVAC:Sizing
design_specification_multispeed_object_type
Design Specification Multispeed Object Type
choice Enter the type of performance specification object used to describe the multispeed coil or fan.
One of UnitarySystemPerformance:Multispeed
design_specification_multispeed_object_name
Design Specification Multispeed Object Name
reference The name of the performance specification object used to describe the multispeed coil or fan.
Names a UnitarySystemPerformance:Multispeed
dx_heating_coil_sizing_ratio
DX Heating Coil Sizing Ratio
number 1.0 Used to adjust heat pump heating capacity with respect to DX cooling capacity used only for heat pump configurations (i.e., a DX cooling and DX heating coil is used).
Range: > 0
Referenced by 4 object types

AirTerminal:SingleDuct:Mixer, FaultModel:TemperatureSensorOffset:CoilSupplyAir, SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList

ZoneHVAC:WindowAirConditioner

from idfpy.models import ZoneHVACWindowAirConditioner

Window air conditioner. Forced-convection cooling-only unit with supply fan, direct expansion (DX) cooling coil, and fixed-position outdoor air mixer.

Field Type Default Details
name
Name required
string
availability_schedule_name
Availability Schedule Name
reference Availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
maximum_supply_air_flow_rate
Maximum Supply Air Flow Rate required
number or Autosize
m3/s
maximum_outdoor_air_flow_rate
Maximum Outdoor Air Flow Rate required
number or Autosize
m3/s
air_inlet_node_name
Air Inlet Node Name required
string
air_outlet_node_name
Air Outlet Node Name required
string
outdoor_air_mixer_object_type
Outdoor Air Mixer Object Type required
choice currently only one OutdoorAir:Mixer object type is available.
One of OutdoorAir:Mixer
outdoor_air_mixer_name
Outdoor Air Mixer Name required
reference Names a OutdoorAir:Mixer
supply_air_fan_object_type
Supply Air Fan Object Type required
choice Fan:ConstantVolume only works when continuous fan operation is used the entire simulation (all supply air fan operating mode schedule values are greater than 0). If any fan operating mode schedule values are 0 a Fan:SystemModel or Fan:OnOff object must be used.
One of Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel
supply_air_fan_name
Supply Air Fan Name required
reference Fan type Fan:ConstantVolume is used with continuous fan and fan type Fan:OnOff is used with cycling Fan.
Names a Fan:ConstantVolume, Fan:OnOff, Fan:SystemModel
cooling_coil_object_type
Cooling Coil Object Type required
choice One of Coil:Cooling:DX:SingleSpeed, Coil:Cooling:DX:VariableSpeed, CoilSystem:Cooling:DX:HeatExchangerAssisted
dx_cooling_coil_name
DX Cooling Coil Name required
reference Names a Coil:Cooling:DX:SingleSpeed, Coil:Cooling:DX:SingleSpeed:ThermalStorage, Coil:Cooling:DX:VariableSpeed, CoilSystem:Cooling:DX:HeatExchangerAssisted
supply_air_fan_operating_mode_schedule_name
Supply Air Fan Operating Mode Schedule Name
reference Enter the name of a schedule that controls fan operation. Schedule Name values of 0 denote cycling fan operation (fan cycles with cooling coil). Schedule values greater than 0 denote constant fan operation (fan runs continually regardless of coil operation). The fan operating mode defaults to cycling fan operation if this field is left blank.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
fan_placement
Fan Placement required
choice One of BlowThrough, DrawThrough
cooling_convergence_tolerance
Cooling Convergence Tolerance
number 0.001 Range: > 0
availability_manager_list_name
Availability Manager List Name
reference Enter the name of an AvailabilityManagerAssignmentList object.
Names a AvailabilityManagerAssignmentList
design_specification_zonehvac_sizing_object_name
Design Specification ZoneHVAC Sizing Object Name
reference Enter the name of a DesignSpecificationZoneHVACSizing object.
Names a DesignSpecification:ZoneHVAC:Sizing
Referenced by 2 object types

SpaceHVAC:ZoneEquipmentSplitter, ZoneHVAC:EquipmentList