Air Distribution

14 object types from idfpy.models.air_distribution · EnergyPlus 26.2

Object Summary
AirLoopHVAC Defines a central forced air system.
AirLoopHVAC:DedicatedOutdoorAirSystem Defines a central forced air system to provide dedicated outdoor air to multiple AirLoopHVACs.
AirLoopHVAC:ExhaustSystem Defines a general exhaust system with a central exhaust fan drawing from one or more ZoneHVAC:ExhaustControl …
AirLoopHVAC:Mixer Mix N inlet air streams from Relief Air Stream Node in OutdoorAir:Mixer objects served by AirLoopHVAC objects …
AirLoopHVAC:OutdoorAirSystem Outdoor air subsystem for an AirLoopHVAC.
AirLoopHVAC:OutdoorAirSystem:EquipmentList List equipment in simulation order
AirLoopHVAC:ReturnPath A return air path can only contain one AirLoopHVAC:ZoneMixer and one or more AirLoopHVAC:ReturnPlenum objects.
AirLoopHVAC:ReturnPlenum Connects N zone inlet air streams, through zone return plenum, to outlet (currently 500 per air loop) Node …
AirLoopHVAC:Splitter Split one air stream from AirLoopHVAC:DedicatedOutdoorAirSystem outlet node into N outlet streams (currently …
AirLoopHVAC:SupplyPath A supply path can only contain AirLoopHVAC:ZoneSplitter and AirLoopHVAC:SupplyPlenum objects which may be in …
AirLoopHVAC:SupplyPlenum Connects 1 zone inlet air stream, through zone supply plenum, to one or more outlets.
AirLoopHVAC:ZoneMixer Mix N inlet air streams into one (currently 500 per air loop, but extensible).
AirLoopHVAC:ZoneSplitter Split one air stream into N outlet streams (currently 500 per air loop, but extensible).
OutdoorAir:Mixer Outdoor air mixer.

AirLoopHVAC

from idfpy.models import AirLoopHVAC

Defines a central forced air system.

Field Type Default Details
name
Name required
string
controller_list_name
Controller List Name
reference Enter the name of an AirLoopHVAC:ControllerList object.
Names a AirLoopHVAC:ControllerList
availability_manager_list_name
Availability Manager List Name
reference Enter the name of an AvailabilityManagerAssignmentList object.
Names a AvailabilityManagerAssignmentList
design_supply_air_flow_rate
Design Supply Air Flow Rate
number or Autosize
m3/s
0.0
branch_list_name
Branch List Name required
reference Name of a BranchList containing all the branches in this air loop
Names a BranchList
connector_list_name
Connector List Name
reference Name of a ConnectorList containing all the splitters and mixers in the loop
Names a ConnectorList
supply_side_inlet_node_name
Supply Side Inlet Node Name required
string Name of inlet node where air enters the supply side of the air loop. If this air loop has a return path, then this node is where return air enters the supply side. If this air loop has no return path, then this node is where outdoor air or other air enters the supply side.
demand_side_outlet_node_name
Demand Side Outlet Node Name
string Name of outlet node where return air leaves the demand side and enters the supply side. Required if this air loop has a return path. Leave this field blank if there is no return.
demand_side_inlet_node_names
Demand Side Inlet Node Names required
string Name of a Node or NodeList containing the inlet node(s) supplying air to zone equipment.
supply_side_outlet_node_names
Supply Side Outlet Node Names required
string Name of a Node or NodeList containing the outlet node(s) supplying air to the demand side.
design_return_air_flow_fraction_of_supply_air_flow
Design Return Air Flow Fraction of Supply Air Flow
number 1.0 The design return air flow rate as a fraction of supply air flow rate with no exhaust. This can be used to model a pressurized system or set to zero to model a DOAS with no return flow. Use ZoneAirMassFlowConservation to balance zone infiltration and mixing flows.
Range: ≥ 0
Referenced by 16 object types

AirLoopHVAC:DedicatedOutdoorAirSystem, AvailabilityManager:HybridVentilation, Duct:Loss:Conduction, Duct:Loss:Leakage, Duct:Loss:MakeupAir, SetpointManager:Coldest, SetpointManager:MultiZone:Cooling:Average, SetpointManager:MultiZone:Heating:Average, SetpointManager:MultiZone:Humidity:Maximum, SetpointManager:MultiZone:Humidity:Minimum, SetpointManager:MultiZone:MaximumHumidity:Average, SetpointManager:MultiZone:MinimumHumidity:Average, SetpointManager:ReturnAirBypassFlow, SetpointManager:Warmest, SetpointManager:WarmestTemperatureFlow, Sizing:System

AirLoopHVAC:DedicatedOutdoorAirSystem

from idfpy.models import AirLoopHVACDedicatedOutdoorAirSystem extensible

Defines a central forced air system to provide dedicated outdoor air to multiple AirLoopHVACs.

Field Type Default Details
name
Name required
string
airloophvac_outdoorairsystem_name
AirLoopHVAC:OutdoorAirSystem Name
reference Enter the name of an AirLoopHVAC:OutdoorAirSystem object.
Names a AirConditioner:VariableRefrigerantFlow, AirLoopHVAC:OutdoorAirSystem, AirLoopHVAC:Unitary:Furnace:HeatCool, AirLoopHVAC:Unitary:Furnace:HeatOnly, AirLoopHVAC:UnitaryHeatCool, AirLoopHVAC:UnitaryHeatCool:VAVChangeoverBypass, AirLoopHVAC:UnitaryHeatOnly, AirLoopHVAC:UnitaryHeatPump:AirToAir, AirLoopHVAC:UnitaryHeatPump:AirToAir:MultiSpeed, AirLoopHVAC:UnitaryHeatPump:WaterToAir, AirLoopHVAC:UnitarySystem, AirTerminal:SingleDuct:ConstantVolume:CooledBeam and 125 more
availability_schedule_name
Availability Schedule Name
reference Availability schedule name for this system. Schedule value > 0 means the system is available. If this field is blank, the system is always available.
Names a ExternalInterface:FunctionalMockupUnitExport:To:Schedule, ExternalInterface:FunctionalMockupUnitImport:To:Schedule, ExternalInterface:Schedule, Schedule:Compact, Schedule:Constant, Schedule:File, Schedule:Year, Schedule:Year:Rules
airloophvac_mixer_name
AirLoopHVAC:Mixer Name required
reference Name of AirLoopHVAC:Mixer.
Names a AirLoopHVAC:Mixer
airloophvac_splitter_name
AirLoopHVAC:Splitter Name required
reference Name of AirLoopHVAC:Splitter.
Names a AirLoopHVAC:Splitter
preheat_design_temperature
Preheat Design Temperature required
number
C
preheat_design_humidity_ratio
Preheat Design Humidity Ratio required
number
kgWater/kgDryAir
precool_design_temperature
Precool Design Temperature required
number
C
precool_design_humidity_ratio
Precool Design Humidity Ratio required
number
kgWater/kgDryAir
number_of_airloophvac
Number of AirLoopHVAC required
integer Enter the number of the AirLoopHVAC served by AirLoopHVAC:DedicatedOutdoorAirSystem
airloophvacs list Each item: airloophvac_name

AirLoopHVAC:ExhaustSystem

from idfpy.models import AirLoopHVACExhaustSystem

Defines a general exhaust system with a central exhaust fan drawing from one or more ZoneHVAC:ExhaustControl outlet nodes via an AirLoopHVAC:ZoneMixer.

Field Type Default Details
name
Name required
string Name of the exhaust system
zone_mixer_name
Zone Mixer Name required
reference The name of the exhaust system AirLoopHVAC:ZoneMixer
Names a AirLoopHVAC:ZoneMixer
fan_object_type
Fan Object Type required
choice One of Fan:ComponentModel, Fan:SystemModel
fan_name
Fan Name required
reference Names a Fan:ComponentModel, Fan:SystemModel

AirLoopHVAC:Mixer

from idfpy.models import AirLoopHVACMixer extensible

Mix N inlet air streams from Relief Air Stream Node in OutdoorAir:Mixer objects served by AirLoopHVAC objects listed in AirLoopHVAC:DedicatedOutdoorAirSystem into one (currently 10 as default, but extensible). Node names cannot be duplicated within a single mixer list.

Field Type Default Details
name
Name required
string
outlet_node_name
Outlet Node Name required
string
nodes list Each item: inlet_node_name
Referenced by 1 object types

AirLoopHVAC:DedicatedOutdoorAirSystem

AirLoopHVAC:OutdoorAirSystem

from idfpy.models import AirLoopHVACOutdoorAirSystem

Outdoor air subsystem for an AirLoopHVAC. Includes an outdoor air mixing box and optional outdoor air conditioning equipment such as heat recovery, preheat, and precool coils. From the perspective of the primary air loop the outdoor air system is treated as a single component.

Field Type Default Details
name
Name required
string
controller_list_name
Controller List Name
reference Enter the name of an AirLoopHVAC:ControllerList object or blank if this object is used in AirLoopHVAC:DedicatedOutdoorAirSystem.
Names a AirLoopHVAC:ControllerList
outdoor_air_equipment_list_name
Outdoor Air Equipment List Name required
reference Enter the name of an AirLoopHVAC:OutdoorAirSystem:EquipmentList object.
Names a AirLoopHVAC:OutdoorAirSystem:EquipmentList
Referenced by 2 object types

AirLoopHVAC:DedicatedOutdoorAirSystem, Branch

AirLoopHVAC:OutdoorAirSystem:EquipmentList

from idfpy.models import AirLoopHVACOutdoorAirSystemEquipmentList

List equipment in simulation order

Field Type Default Details
name
Name required
string
component_1_object_type
Component 1 Object Type required
reference Names a
component_1_name
Component 1 Name required
reference Names a AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, Coil:UserDefined, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water, CoilSystem:Cooling:Water:HeatExchangerAssisted, CoilSystem:Heating:DX and 20 more
component_2_object_type
Component 2 Object Type
reference Names a
component_2_name
Component 2 Name
reference Names a AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, Coil:UserDefined, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water, CoilSystem:Cooling:Water:HeatExchangerAssisted, CoilSystem:Heating:DX and 20 more
component_3_object_type
Component 3 Object Type
reference Names a
component_3_name
Component 3 Name
reference Names a AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, Coil:UserDefined, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water, CoilSystem:Cooling:Water:HeatExchangerAssisted, CoilSystem:Heating:DX and 20 more
component_4_object_type
Component 4 Object Type
reference Names a
component_4_name
Component 4 Name
reference Names a AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, Coil:UserDefined, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water, CoilSystem:Cooling:Water:HeatExchangerAssisted, CoilSystem:Heating:DX and 20 more
component_5_object_type
Component 5 Object Type
reference Names a
component_5_name
Component 5 Name
reference Names a AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, Coil:UserDefined, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water, CoilSystem:Cooling:Water:HeatExchangerAssisted, CoilSystem:Heating:DX and 20 more
component_6_object_type
Component 6 Object Type
reference Names a
component_6_name
Component 6 Name
reference Names a AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, Coil:UserDefined, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water, CoilSystem:Cooling:Water:HeatExchangerAssisted, CoilSystem:Heating:DX and 20 more
component_7_object_type
Component 7 Object Type
reference Names a
component_7_name
Component 7 Name
reference Names a AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, Coil:UserDefined, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water, CoilSystem:Cooling:Water:HeatExchangerAssisted, CoilSystem:Heating:DX and 20 more
component_8_object_type
Component 8 Object Type
reference Names a
component_8_name
Component 8 Name
reference Names a AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, Coil:UserDefined, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water, CoilSystem:Cooling:Water:HeatExchangerAssisted, CoilSystem:Heating:DX and 20 more
component_9_object_type
Component 9 Object Type
reference Names a
component_9_name
Component 9 Name
reference Names a AirLoopHVAC:UnitarySystem, Coil:Cooling:Water, Coil:Cooling:Water:DetailedGeometry, Coil:Heating:Electric, Coil:Heating:Fuel, Coil:Heating:Steam, Coil:Heating:Water, Coil:UserDefined, CoilSystem:Cooling:DX, CoilSystem:Cooling:Water, CoilSystem:Cooling:Water:HeatExchangerAssisted, CoilSystem:Heating:DX and 20 more
Referenced by 1 object types

AirLoopHVAC:OutdoorAirSystem

AirLoopHVAC:ReturnPath

from idfpy.models import AirLoopHVACReturnPath extensible

A return air path can only contain one AirLoopHVAC:ZoneMixer and one or more AirLoopHVAC:ReturnPlenum objects.

Field Type Default Details
name
Name required
string
return_air_path_outlet_node_name
Return Air Path Outlet Node Name required
string
components list Each item: component_object_type, component_name

AirLoopHVAC:ReturnPlenum

from idfpy.models import AirLoopHVACReturnPlenum extensible

Connects N zone inlet air streams, through zone return plenum, to outlet (currently 500 per air loop) Node names cannot be duplicated within a single plenum list.

Field Type Default Details
name
Name required
string
zone_name
Zone Name required
reference Names a Zone
zone_node_name
Zone Node Name required
string
outlet_node_name
Outlet Node Name required
string
induced_air_outlet_node_or_nodelist_name
Induced Air Outlet Node or NodeList Name
string
nodes list Each item: inlet_node_name
Referenced by 1 object types

AirLoopHVAC:ReturnPath

AirLoopHVAC:Splitter

from idfpy.models import AirLoopHVACSplitter extensible

Split one air stream from AirLoopHVAC:DedicatedOutdoorAirSystem outlet node into N outlet streams (currently 10 as default, but extensible). Node names should be Outdoor Air Stream Node Name in OutdoorAir:Mixer objects served by AirLoopHVAC objects listed in AirLoopHVAC:DedicatedOutdoorAirSystem.

Field Type Default Details
name
Name required
string
inlet_node_name
Inlet Node Name required
string
nodes list Each item: outlet_node_name
Referenced by 1 object types

AirLoopHVAC:DedicatedOutdoorAirSystem

AirLoopHVAC:SupplyPath

from idfpy.models import AirLoopHVACSupplyPath extensible

A supply path can only contain AirLoopHVAC:ZoneSplitter and AirLoopHVAC:SupplyPlenum objects which may be in series or parallel.

Field Type Default Details
name
Name required
string
supply_air_path_inlet_node_name
Supply Air Path Inlet Node Name required
string
components list Each item: component_object_type, component_name

AirLoopHVAC:SupplyPlenum

from idfpy.models import AirLoopHVACSupplyPlenum extensible

Connects 1 zone inlet air stream, through zone supply plenum, to one or more outlets. Node names cannot be duplicated within a single supply plenum list.

Field Type Default Details
name
Name required
string
zone_name
Zone Name required
reference Names a Zone
zone_node_name
Zone Node Name required
string
inlet_node_name
Inlet Node Name required
string
nodes list Each item: outlet_node_name
Referenced by 1 object types

AirLoopHVAC:SupplyPath

AirLoopHVAC:ZoneMixer

from idfpy.models import AirLoopHVACZoneMixer extensible

Mix N inlet air streams into one (currently 500 per air loop, but extensible). Node names cannot be duplicated within a single zone mixer (AirLoopHVAC:ZoneMixer) list.

Field Type Default Details
name
Name required
string
outlet_node_name
Outlet Node Name required
string
nodes list Each item: inlet_node_name
Referenced by 5 object types

AirLoopHVAC:ExhaustSystem, AirLoopHVAC:ReturnPath, AirTerminal:SingleDuct:ConstantVolume:FourPipeInduction, AirTerminal:SingleDuct:ParallelPIU:Reheat, AirTerminal:SingleDuct:SeriesPIU:Reheat

AirLoopHVAC:ZoneSplitter

from idfpy.models import AirLoopHVACZoneSplitter extensible

Split one air stream into N outlet streams (currently 500 per air loop, but extensible). Node names cannot be duplicated within a single zone splitter (AirLoopHVAC:ZoneSplitter) list.

Field Type Default Details
name
Name required
string
inlet_node_name
Inlet Node Name required
string
nodes list Each item: outlet_node_name
Referenced by 1 object types

AirLoopHVAC:SupplyPath

OutdoorAir:Mixer

from idfpy.models import OutdoorAirMixer

Outdoor air mixer. Node names cannot be duplicated within a single OutdoorAir:Mixer object or across all outdoor air mixers.

Field Type Default Details
name
Name required
string
mixed_air_node_name
Mixed Air Node Name required
string Name of Mixed Air Node
outdoor_air_stream_node_name
Outdoor Air Stream Node Name required
string Name of Outdoor Air Stream Node
relief_air_stream_node_name
Relief Air Stream Node Name required
string Name of Relief Air Stream Node
return_air_stream_node_name
Return Air Stream Node Name required
string Name of Return Air Stream Node
Referenced by 10 object types

AirLoopHVAC:OutdoorAirSystem:EquipmentList, AirLoopHVAC:UnitaryHeatCool:VAVChangeoverBypass, AirflowNetwork:Distribution:Component:OutdoorAirFlow, AirflowNetwork:Distribution:Component:ReliefAirFlow, ZoneHVAC:FourPipeFanCoil, ZoneHVAC:PackagedTerminalAirConditioner, ZoneHVAC:PackagedTerminalHeatPump, ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, ZoneHVAC:WaterToAirHeatPump, ZoneHVAC:WindowAirConditioner